The resistance S'' and S_{1} are combined in a slide-wire resistance-box
and are used to change the value of the whole apparatus when there are
marked changes in the position of the thermometric scale. Thus, if the
ingoing water is at 2° C. and the outcoming water at 5° C. in one
instance, and in another instance the ingoing water is 13° and the
outgoing water is 15°, a slight alteration in the value of S_{1}, and
also of S', is necessary in order to have the apparatus draw a curve to
represent truly the temperature differences. These slight alterations
are determined beforehand by careful tests and the exact value of the
resistances in S' and in S_{1} are permanently recorded for subsequent
use.
THE GALVANOMETER.
The galvanometer is of the Deprez-d'Arsonval type and has a particularly
powerful magnetic field, in which a double coil swings suspended similar
to the marine galvanometer coils. This coil is protected from vibrations
by an anti-vibration tube A, fig. 20, and carries a pointer P which acts
to select the direction of movement of the recording apparatus, the
movable contact point _q_, fig. 19. In front of this galvanometer coil
and inclosed in the same air-tight metal case is the plunger contact Pl,
fig. 21. The galvanometer pointer P swings freely below the silver
contacts S_{1} and S_{2}, just clearing the ivory insulator _i_. The
magnet plunger makes a contact depending upon the adjustment of a clock
at intervals of 2 seconds. So long as both galvanometer coils are
influenced by exactly the same strength of current, the pointer will
stand in line with and immediately below _i_ and no current passes
through the recording apparatus. Any disturbance of the electrical
equilibrium causes the pointer P to swing either toward S_{1} or S_{2},
thus completing the circuit at either the right hand or the left hand,
at intervals of 2 seconds. The movement of the pointer away from its
normal position exactly beneath _i_ to either S_{1} on the left hand or
S_{2} on the right, results from an inequality in the current flowing
through the two coils in the galvanometer. The difference in the two
currents passing through these coils is caused by a change in
temperatures of the two thermometers in the water circuit.
[Illustration: FIG. 20.--Diagram of galvanometer coil used in connection
with recording apparatus for resistance thermometers in the
water-circuit of bed calorimeter. A, anti-vibration tube; P, pointer.]
THE CREEPER.