=148.= In stating the information for windows, full details are needed
as to whether they are single- or double-hung, French casement,
stationary, or ordinary casement. Double-hung windows 20 inches or
less in width require only one sash lift. Extra-wide windows, such as
those over 36 inches, should have either bar lifts or two extra-heavy
hook sash lifts. The window stops should be studied in detail, so as to
estimate the number of screws that will be required for each window.
In the case of French windows, it is well to determine the height,
the width of the stile, whether the joints are rabbeted, beveled,
or flat, the hand, and whether the windows swing in or out; detail
cross-sections through head-jambs, casing, and lock stiles should
also be procured if possible. In casement sash, the pivoting should
be noted, so as to determine whether it is vertical or horizontal;
the swing should also be observed, and if the sash are to be hinged,
determine whether the hinges should be placed at the top, the bottom,
or the sides. As in the consideration of doors, the thicknesses and
sizes of all casements should always be noted. Sections through the
jambs, trim, and stiles should be taken at the points where the
hardware is to be applied.
=149.= In order to determine the kind and length of the lifters to
be used on the transoms, it is necessary to note the distance from
the floor to the center of each transom, also whether they are to be
pivoted or hinged from the bottom or the top, and how they are to
swing. The cross-section through side jambs and casings should always
be ascertained, in order to see that the hardware will be suitable to
meet the conditions of the trim.
=150.= It is necessary to learn all details of the pantry, including
the thickness and height of doors, whether they are double or single,
and the number of each kind. Note all drawers; those under 20 inches
in width require only one pull. The details of the flour bins should
be examined to determine whether they are to be hinged at the bottom
and are to tilt, or whether they are to be curved on plan and are to be
hinged at the side, as each condition requires different hardware.
=151.= Where unavoidable interferences are discovered, or where the
plans and specifications are obscure or defective, a note of the facts
should be made, and when all such matters have been collected, they
should be submitted to the architect for his decision as a basis for
final determination.