3. In order to remove the impure air, there should be ventilators provided
at or near the floor, opening into air shafts, or pipes leading upward
through the roof, with proper orifices at the top. These ventilating pipes
should be heated artificially so as to produce a draught. They may form
one of the flues of a chimney in which there is a constant fire; or be
carried upward in a large flue through the center of which runs the smoke
pipe of the furnace or stove; [Footnote: This plan has been adopted in the
newer school buildings of Elmira, N. Y. The older buildings were provided
with ventilating pipes, not heated artificially, and hence of no service.
These pipes are rendered effective, however, by conducting them into a
small room in the garret, heated by a coal stove. From this room, a large
exit pipe leads to the roof, where it terminates in an Emerson's
ventilator. So strong a draught is thus established that throughout the
building air is taken from the floors, and consequently the cooler portion
of the rooms, at a velocity of three to five feet per second or one
hundred and eighty to three hundred cubic feet per minute for each square
foot of flue opening. In perpendicular flues, heated throughout with a
smoke flue from the furnace, ten feet per second is attained.] or the
ventilating pipe be itself conveyed through the center of the larger
chimney flue. If the register for hot air be on the floor at one side of
the room, two or more ventilators may be placed near the floor on the
opposite side. The warm air will thus make the complete circuit of the
room, and thoroughly warm it before passing out.
If the ventilating shaft be not heated artificially; the ventilator must
be placed at the top of the room in order that the hot air may escape
through it, thus producing an upward draught. But the objection to this
method is that it allows the warmer air to escape, while economy requires
that the cooler air at the bottom of the room should be removed and the
warm air be made to descend, thus securing uniformity of temperature.
4. In the summer, ventilation may be commonly provided for by opening
windows _at the top and the bottom_, on the sheltered side of the
building, so as to avoid draughts of air injurious to the occupants. On a
dull, still, hot day, when there is little difference of temperature
between the inner and the outer air, ventilation can be secured only by
having a fire provided in the ventilating shaft; this, by exhausting the
air from the room, will cause a fresh current to pour in through the open
windows. At recess, all the children should, if the weather permit, be
sent out of doors, to allow their clothing to be exposed to the purifying
influence of the open air; meantime, the windows should be thrown wide
open, that the room may be thoroughly ventilated during their absence. In
bad weather, rapid marching or calisthenic exercises will furnish
exercise, and also permit the airing of the room.