_Second procedure._—For surface waters containing small amounts of
organic matter, the method of Klut[59] is recommended. Samples
containing small amounts of iron should be concentrated, if possible,
until at least 0.5 mg. of iron is present in the volume tested. Boil the
sample in a beaker with 2 to 3 cc. of concentrated nitric acid free from
iron, adding permanganate if necessary to destroy the organic matter. To
the hot liquid add ammonia in slight excess and warm until the smell of
ammonia is hardly discernible. Filter and wash with water at 70° to 80°
C. containing a little ammonia. Dissolve the iron in the beaker and on
the filter paper in 5 cc. of concentrated hydrochloric acid, and wash
with hot water until the iron is all dissolved, collecting the filtrate
in a 50 cc. Nessler tube. Dilute to 50 cc. Add potassium sulfocyanide
and determine the iron by comparison with standards.
COMPARISON WITH IRON STANDARDS.
_First procedure._—Prepare standards containing amounts of standard iron
solution ranging from 0.05 to 4 cc. according to the quantity of iron in
the sample. Dilute these amounts with water to about 40 cc. Add 5 cc. of
dilute hydrochloric acid and 3 drops of potassium permanganate to each
tube and dilute to 50 cc. Add 5 cc. of the potassium sulfocyanide to
each of the standard solutions at the same time that it is added to the
samples of water under examination, and compare immediately after
mixing. If 100 cc. of the sample is used the iron in parts per million
is equal to the number of cubic centimeters of the standard iron
solution in the standard that the sample matches.
_Second procedure._—For a small number of determinations it is more
convenient to run the standard iron solution into a Nessler tube
containing the acid, distilled water, and potassium sulfocyanide until
the color matches that of the sample tested. When determining iron in
three or four samples the colors may be matched in the order of their
intensity and the volumes of standard iron solution required for each
tube may be read from the burette.
COMPARISON WITH PERMANENT STANDARDS.
_Reagents._—1. Platinum solution. Dissolve 2 grams of potassium platinic
chloride (PtCl_{4}.2KCl) in distilled water, add 100 cc. of concentrated
hydrochloric acid, and dilute to 1 liter with distilled water.
2. Cobalt solution. Dissolve 24 grams of dry cobaltous chloride crystals
(CoCl_{2}.6H_{2}O) in a small amount of distilled water, add 100 cc. of
strong hydrochloric acid, and dilute to 1 liter with distilled water.
_Procedure._—Prepare a series of permanent standards by diluting to 50
cc. with distilled water the amounts of platinum and cobalt solutions,
in 50 cc. Nessler tubes, indicated in Table 9. Compare the sample with
these standards, and calculate the parts per million of iron.
Table 9.—PREPARATION OF PERMANENT STANDARDS FOR THE DETERMINATION OF
IRON.