A very important economical consideration should be noted in laying
out the arrangement of the bathroom fixtures in this connection. The
horizontal branch soil-lines and waste-lines must be carried through
the floor construction, and they should be so arranged that they can
run parallel with the floor-joists; otherwise deep cuts will have to be
made in them. In the case of the branch soil-line it is essential to
place the water-closet as near to the main soil-stack as possible, for
with a 4-inch pipe the joists must be framed around it rather than be
cut, since so deep a gouge would weaken too much the strength of them. A
similar consideration must be given to the framing in stud partitions
which are bearing the loads of the floors above, for too deep cuts in
them, to allow for the passage of pipes, will weaken them greatly. In
this connection it ought to be noted that an ordinary 4-inch soil-pipe
cannot be carried in a stud partition made with 2 by 4 studs, since
the outer edges of the joints of the pipe will project beyond the face
of the plaster, and for this reason some convenient place should be
planned for them in closets, or 2 by 6 studs should be used in the
partition through which they are run.
_The More Complicated Back-Vent System_
The essential parts of the plumbing system remain the same as described
above, but each trap is considered to be siphonable, and must be
prevented from losing its water-seal by the use of back-venting pipes.
Whenever, then, there is an unusual amount of semi-vacuum created
in the pipes by the discharge of some fixture above, the outside
air-pressure can relieve it by passing through the back vents rather
than by forcing out the water-seal in the traps. The usual type of
trap employed is the modified S trap with the small TY connection to
give what is known as continuous venting. Formerly the vent was taken
off from the crown of the three-quarter-S trap, which was too near the
surface of the water-seal, causing excessive evaporation and danger of
clogging, but with the continuous system of venting, the waste-pipe
is a continuation of the vent-line, and the trap enters into its side
through a TY fitting, overcoming the disadvantage of the older system.
The size of traps should conform to the size of waste-pipes, and
usually the size of the branch vents is about the same size as the
waste-lines. However, there are special conditions where this varies.
For venting the water-closet trap, it should be noted that the vent is
not taken from the trap which is contained within the fixture itself,
but is taken from the upper side of the bend (usually of lead) where
the fixture is joined with the piping system, and is 2 inches in
diameter.
[Illustration: PLUMBING SYSTEM USING BACK-VENTING]