A Manual of Photographic Chemistry, Including the Practice of the Collodion ProcessHardwich, T. Frederick
Science
A Manual of Photographic Chemistry, Including the Practice of the Collodion Process
Hardwich, T. Frederick
Photographic chemistry; Photography
The time of exposure must be varied according to the intensity of the
light, the sensibility of the Collodion, and the degree of magnifying
power; a few seconds to a minute will be about the extremes; but minute
directions are not required, as the operator, if a good Photographer, will
easily ascertain the proper time for exposing (see page 224).
At this point a difficulty will probably occur from the plane of the
chemical focus not corresponding, as a rule, with that of the visual
focus. This arises from the fact that the object-glasses of Microscopes
are "over-corrected" for colour, in order to compensate for a little
chromatic aberration in the eye-piece. The violet rays, in consequence
of the over-correction, are projected _beyond_ the yellow, and hence the
focus of chemical action is further from the glass than the visible image.
The allowance may be made by shifting the sensitive plate, or, what
amounts to the same thing, by removing the object-glass a little _away_
from the object with the fine adjustment screw; the latter is the most
convenient. The exact distance must be determined by careful experiment
for each glass; but it is greatest with the low powers, and decreases as
they ascend.
Mr. Shadbolt gives the following as a guide:--"An inch and a half
objective of Smith and Beck's make required to be shifted 1/50th of an
inch, or two turns of _their_ fine adjustment; a 2/3rds of an inch,
1/200th of an inch, or half a turn; and a 4/10ths of an inch, 1/1000th
of an inch, or about two divisions of the adjustment. With the 1/4th
and higher powers, the difference between the foci was so small as to be
practically unimportant."
There is also reason to think that the _kind of light_ employed has an
influence upon the separation of the foci. Mr. Delves finds that with
sunlight the difference between them is very small even with the low
powers, and inappreciable with the higher; whereas in using diffused
daylight which has undergone a previous reflection from white clouds, it
is considerable.
The object-glasses of the same maker, and particularly those of different
makers, also vary much; so that it will be necessary to test each glass
separately, and to register the allowance which is required.
Having found the chemical focus, the principal difficulty has been
overcome, and the remaining steps are the same in every respect as for
ordinary Collodion Photographs.
To those who cannot devote their time to Photography during the day,
Mr. Shadbolt's observations on the use of artificial light may be of
service. He employs _Camphine_, which gives a whiter flame than gas, or a
moderator lamp; placing the source of light in the focus of a plano-convex
lens of 2-1/2 to 3 inches diameter (the flat side towards the lamp), and
condensing the parallel rays so obtained on the object, by a second lens
of about 1-1/2-inch diameter and 3-inch focus.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account