Proportion of Salt in 100 parts of water 0 Boiling-point 212 deg.
" " 1/33 " 213.2
" " 2/33 " 214.4
" " 3/33 " 215.5
" " 4/33 " 216.6
" " 5/33 " 217.9
" " 6/33 " 219.0
" " 7/33 " 220.2
" " 8/33 " 221.4
" " 9/33 " 222.5
" " 10/33 " 223.7
" " 11/33 " 224.9
" " 12/33 " 226.0
When the salts in solution amount to 12/33, the water is saturated. It has
also been ascertained that, when a solution of 4/33 is attained,
incrustation of the substances commences on the boiler. Hence, it is a
rule with engineers to expel some of the boiling water, when the
thermometer indicates a temperature of 216 deg., and introduce some more cold
water, in order to prevent incrustation, which not only injures the
boiler, but opposes the passage of heat to the water. The thermometer used
for this purpose should be very accurately graduated, and the scale must
be considerably higher than, though it need not read much below 212 deg.
_2nd. Pressure Gauge._--The elasticity of gases augments by increase of
temperature, and _vice versa_; it follows, therefore, that when steam is
generated in a closed boiler, its temperature rises beyond the boiling
temperature of 212 deg., owing to the increased pressure upon the water. The
law connecting the pressure and the corresponding temperature of steam is
the same as that upon which the boiling of fluids under diminished
atmospheric pressure takes place. Hence, the indications of the
thermometer become exponents of steam pressure. Engineers are furnished,
in works on the steam-engine, with tables, from which the pressure
corresponding to a given temperature, or the converse, can be obtained by
mere inspection.
[Illustration: Fig. 74.]
Fig. 74 represents the thermometer employed as a steam-pressure gauge. It
is fitted in a brass case, with screw-plug and washers for closing the
boiler when the thermometer is not in use. The scale shows the pressure
corresponding to the temperature, from 15 to 120 lbs., above the
atmospheric pressure, which is usually taken as 15 lbs. on the square
inch.
CHAPTER XI.
INSTRUMENTS FOR ASCERTAINING THE HUMIDITY OF THE AIR.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account