Acetylene, the Principles of Its Generation and Use: A Practical Handbook on the Production, Purification, and Subsequent Treatment of Acetylene for the Development of Light, Heat, and PowerLeeds, F. H. (Frank Henley)
Science
Acetylene, the Principles of Its Generation and Use: A Practical Handbook on the Production, Purification, and Subsequent Treatment of Acetylene for the Development of Light, Heat, and Power
Leeds, F. H. (Frank Henley)
Acetylene
The third section deals with generator houses, which must be well
ventilated and light; must not be used for any other purpose except to
store one day's consumption of carbide, not exceeding 300 kilos.; must be
fire-proof; must have doors opening outwards; and the vent-pipes must
terminate at a safe place in the open. Apparatus of group (_b_) must
not be placed in a dwelling-room and only in an adjoining room if the
gasholder is of less than 600 litres capacity. Apparatus of group
(_c_) must be in an independent building which must be at least 33
feet from occupied premises if the capacity of the gasholder is 6000
litres and upwards. Half this distance suffices for gasholders containing
600 to 6000 litres. These distances may be reduced at the discretion of
the local authorities provided a substantial partition wall at least 1
foot thick is erected. Apparatus of group (_d_) must be at least 50
feet from occupied premises and the gasholder and generator must not be
in the same building.
The fourth section deals with the question of authorisation for the
installation of acetylene plant. Apparatus of group (_a_) may be
installed without obtaining permission from any authorities. In regard to
apparatus of the other groups, permission for installation must be
obtained from local or other authorities.
The fifth section relates to the working of acetylene plant. It makes the
concessionaires and owners of the plant responsible for the manipulation
and supervision of the apparatus, and for the employment of suitable
operators, who must not be less than 18 years of age.
The sixth section relates to the inspection of acetylene plant from time
to time by inspectors appointed by the local or other authorities.
Apparatus of group (_a_) is not subject to these periodical
inspections.
The seventh section details the fees payable for the inspection of
installations and carbide stores, and fixes the penalties for non-
compliance with the regulations.
The eighth section refers to the notification of the position and
description of all carbide works, stores, and acetylene installations to
the local authorities.
The HUNGARIAN GOVERNMENT rules for the construction and examination of
acetylene plant forbid the use of copper and of its alloys; cocks,
however, may be made of a copper alloy. The temperature in the gas space
of a fixed generator must not exceed 50° C., in that of a portable
apparatus 80° C. The maximum effective pressure permissible is 0.15
atmosphere.
The CONSEIL D'HYGIÈNE DE LA SEINE IN FRANCE allows a maximum pressure of
1.5 metres, i.e., 59 inches, of water column in generators used for the
ordinary purposes of illumination; but apparatus intended to supply gas
to the low-pressure oxy-acetylene blowpipe (see Chapter IX.) may develop
up to 2.5 metres, or 98.5 inches of water pressure, provided copper and
its alloys are entirely excluded from the plant and from the delivery-
pipes.