Acetylene, the Principles of Its Generation and Use: A Practical Handbook on the Production, Purification, and Subsequent Treatment of Acetylene for the Development of Light, Heat, and PowerLeeds, F. H. (Frank Henley)
Science
Acetylene, the Principles of Its Generation and Use: A Practical Handbook on the Production, Purification, and Subsequent Treatment of Acetylene for the Development of Light, Heat, and Power
Leeds, F. H. (Frank Henley)
Acetylene
quarter at least, and renewed immediately it shows signs of cracking.
Generally speaking all the fittings used should be characterised by
structural simplicity; any ornamental or decorative effects desired may
be secured by proper design without sacrifice of the simplicity which
should always mark the essential and operative parts of the fitting.
Flexible connexions between the fixed service-pipe and a semi-portable or
temporary burner may at times be required. If the connexion is for
permanent use, it must not be of rubber, but of the metallic flexible
tubing which is now commonly employed for such connexions in the case of
coal-gas. There should be a tap between the service-pipe and the flexible
connexion, and this tap should be turned off whenever the burner is out
of use, so that the connexion is not at other times under the pressure
which is maintained in the service-pipes. Unless the connexion is very
short--say 2 feet or less--there should also be a tap at the burner.
These flexible connexions, though serviceable in the case of table-lamps,
&c., of which the position may have to be altered, are undesirable, as
they increase the risk attendant on gas (whether acetylene or other
illuminating gas) lighting, and should, if possible, be avoided. Flexible
connexions may also be required for temporary use, such as for conveying
acetylene to an optical lantern, and if only occasionally called for, the
cost of the metallic flexible tubing will usually preclude its use. It
will generally be found, however, that the whole connexion in such a case
can be of composition or lead gas-piping, connected up at its two ends by
a few inches of flexible rubber tubing. It should be carried along the
walls or over the heads of people who may use the room, rather than
across the floor, or at a low level, and the acetylene should be turned
on to it only when actually required for use, and turned off at the fixed
service-pipe as soon as no longer required. Quite narrow composition
tubing, say 1/4-inch, will carry all the acetylene required for two or
three burners. The cost of a composition temporary connexion will usually
be less than one of even common rubber tubing, and it will be safer. The
composition tubing must not, of course, be sharply bent, but carried by
easy curves to the desired point, and it should be carefully rolled in a
roll of not less than 18 inches diameter when removed. If these
precautions are observed it may be used very many times.
Public-domain text, read in full here on John Shaqi.