|__________|_________________________________________________________|
| | | | | | | | | | | | |
| 250 | 5.6|15.4|31.6| 87.2|179 |310 | 495| 725|1010|1770|2790|
| 500 | 3.9|10.9|22.4| 61.7|126 |220 | 350| 510| 715|1250|1975|
| 1000 | 2.8| 7.7|15.8| 43.6| 89.5|156 | 245| 360| 505| 885|1395|
| 2000 | 2.0| 5.4|11.2| 30.8| 63.3|110 | 174| 255| 360| 625| 985|
| 3000 | 1.6| 4.4| 9.1| 25.2| 51.7| 90.3| 142| 210| 290| 510| 805|
| 4000 | 1.4| 3.8| 7.9| 21.8| 44.8| 78.2| 123| 181| 250| 440| 695|
|__________|____|____|____|_____|_____|_____|____|____|____|____|____|
| | |
| Length | |
| of Pipe | |
| [_l_] = | Fall of Pressure in the Pipe [_h_] = 2.0 inches. |
| Feet | |
|__________|_________________________________________________________|
| | | | | | | | | | | | |
| 500 | 4.5|12.6|25.8| 71.2|146 |255 | 400| 590| 825|1445|2280|
| 1000 | 3.2| 8.9|18.3| 50.3|103 |180 | 285| 420| 585|1020|1610|
| 2000 | 2.3| 6.3|12.9| 35.6| 73.1|127 | 200| 295| 410| 720|1140|
| 3000 | 1.8| 5.1|10.5| 29.1| 59.7|104 | 164| 240| 335| 590| 930|
| 4000 | 1.6| 4.4| 9.1| 25.2| 51.7| 90.3| 142| 210| 290| 510| 805|
| 5000 | 1.4| 4.0| 8.1| 22.5| 46.2| 80.8| 127| 187| 260| 455| 720|
| 6000 | 1.3| 3.6| 7.4| 20.5| 42.2| 73.7| 116| 171| 240| 415| 655|
|__________|____|____|____|_____|_____|_____|____|____|____|____|____|
NOTE.--In order not to impart to the above table the appearance of the
quantities having been calculated to a degree of accuracy which has no
practical significance, quantities of less than 5 cubic feet have been
ignored when the total quantity exceeds 200 cubic feet, and fractions of
a cubic foot have been included only when the total quantity is less than
100 cubic feet.
TABLE (C).
Giving the Sizes of Pipe which should be used in practice for Acetylene
when the fall of pressure in the Pipe is not to exceed 0.25 inch. (Based
on Morel's formula.)