ASCE 1193: The Water-Works and Sewerage of Monterrey, N. L., Mexico: The 4th article from the June, 1911, Volume LXXII, Transactions of the American Society of Civil Engineers. Paper No. 1193, Feb. 1, 1911.Conway, G. R. G. (George Robert Graham)
Science
ASCE 1193: The Water-Works and Sewerage of Monterrey, N. L., Mexico: The 4th article from the June, 1911, Volume LXXII, Transactions of the American Society of Civil Engineers. Paper No. 1193, Feb. 1, 1911.
+------------------------+-------------+------------+------------+
| DIAMETER | Total labor | Materials. | Total cost |
| OF PIPE : | cost. | Pesos. | per linear |
+--------------+---------+ In pesos. | | meter, in |
| Centimeters. | Inches. | | | pesos. |
+--------------+---------+-------------+------------+------------+
| 10 | 4 | 0.8725 | 3.30 | 4.1725 |
| 15 | 6 | 1.0725 | 4.51 | 5.5825 |
| 30.5 | 12 | 1.565 | 21.35 | 22.915 |
| 38 | 15 | 1.9125 | 22.30 | 24.2125 |
| 45.7 | 18 | 2.2775 | 25.42 | 27.6975 |
| 61 | 24 | 3.665 | 33.20 | 36.865 |
| 76 | 30 | 4.22 | 55.77 | 59.99 |
+--------------+---------+-------------+------------+------------+
The flood destroyed about 1,200 houses in the neighborhood of the river.
In a number of blocks the smaller mains were scoured away, but
considerable salvage was done afterward, and, as it is the intention of
the authorities not to permit rebuilding along the flood-path of the
river, these mains do not require reconstruction.
MAIN SEWERAGE SYSTEM.
The Company's obligations, as far as drainage is concerned, were limited
to the removal and disposal of sewage, no provision being required for
storm-water, which is allowed to find its way to the natural
watercourses. Apart from that fact, however, the best system for a city
like Monterrey, where rainfall for many months at a time is very scarce,
is the strictly "separate system." In the design advantage was taken of
the natural topography of the drainage district, which is almost an
ideal one for a gravitation system of sewers, the general fall in all
directions being northeast; it was also in this direction that the best
available land could be obtained for disposal purposes.
[Illustration: PLATE XX.--DIAGRAM OF THE MAIN SEWERS OF MONTERREY.]
Plate XX shows in skeleton form the general lay-out of the sewers. Two
drainage districts are arranged, divided by Calle de Washington, which may
be regarded as practically the center of the city, and each of these
districts has an independent main collector connecting to the outfall
sewer at the northeast extremity of the city.
The system has been designed so that extensions may be made and may cover
any part within the city limits; the main collectors are large enough for
the whole area when fully built up.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account