Auroræ: Their Characters and SpectraCapron, J. Rand
History
Auroræ: Their Characters and Spectra
Capron, J. Rand
Auroras
The capillary spectrum was mainly distinguished by four bright sharp
lines—one in the red, between the red Aurora-line and D, two in
the green, but considerably more refrangible than the yellow-green
Aurora-line, while the fourth was found to be hydrogen F. The other lines
in the spectrum were considerably fainter, and misty and band-like. The
red line, though not brilliant, was fairly bright and sharp.
The place of the less refrangible of the two bright bands in the
violet-pole spectrum was occupied in the capillary spectrum by a faint
glow only.
[Sidenote: Violet-pole.]
The violet-pole spectrum was recognized by two very bright broad
bands of light in the green, each including within its limits one of
the Aurora-lines. The bright red line in the capillary had a faint
representative in the violet-pole spectrum, as also had the two bright
lines in the green. Other fainter lines appeared in the blue, and three
fairly bright ones towards the violet.
[Sidenote: Dr. Schuster’s remarks on the spectra.]
Dr. Schuster remarks that one of these O bright bands is closely
coincident with a band in the CO spectrum, but that the CO band is bright
towards one edge and fades off gradually thence, while the O band is of
pretty uniform strength throughout. Dr. Schuster finds the wave-lengths
of the violet-pole O bands to be as follows:—
5205·0}
5292·5} Brightest part 5255.
5552·8}
5629·6} Brightest part 5586.
[Sidenote: His tubes free from impurity.]
He also gives as weak bands 5840-5900 and 5969-6010. Dr. Schuster comes
to the conclusion that the green line of the Aurora is not due to
oxygen, as, under considerable dispersion and with good definition, the
oxygen-bands can be broken up into a series of lines, when the brightest
part is found to lie at 5586, which is too much towards the red to
compare with the Aurora-line. He notices that the more refrangible of the
O bands corresponds with a line sometimes seen in the Aurora (Vogel’s
5233). The same remark will, however, apply to this last as to the other
coincidence, viz., that a broad band can hardly represent a line—at
least, the line can only be said to coincide in a loose and indefinite
way. It is evident that Dr. Schuster’s tubes were free from what must
now be considered an impurity in those examined by me and by Dr. Vogel,
and that Mr. Procter’s suspicions of carbon impurities in these, and the
ordinary oxygen-tubes, are thereby quite confirmed.
[Sidenote: Experiments with an open Geissler tube.]
In some experiments which we made (after receiving Dr. Schuster’s tubes)
with an open Geissler tube, so arranged as to connect with an air-pump
and gas-receiver, and thus from time to time to wash out the tube and
vary its contents, we found the same impure spectrum as in the case
of the sealed O tubes; and it seems to require a very large amount of
precaution to avoid these impurities.
[Sidenote: Spectra of Dr. Schuster’s O tube examined.]
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account