These considerations necessitate the determination of the toxicity in
the form of a vapor and not by the ordinary method of administration
by mouth, through the skin (subcutaneously) or through the blood
(intravenously). The simplest method of determining the toxicity of
a substance as a vapor would be to place animals in a gas-tight box
and introduce a known amount of the substance in the form of vapor.
But by this method the concentration is not accurately known unless
chemical analyses of the air are made, and then it is found to be much
less than that calculated from the amount of substance introduced,
because of condensation on the walls of the chamber, or absorption of
the substance by the skin and hair of the animal and in some cases, of
decomposition of the substance by moisture in the air. Moreover, it is
found that the concentration decreases markedly with time. Because of
these factors, the figures used for the concentration are more or less
guess work. To overcome these difficulties, a chamber is used through
which a continuous current of air, containing a known and constant
amount of the poisonous vapor, is passed. Such an apparatus is shown in
Fig. 116.
[Illustration: FIG. 116.—Continuous Flow Gassing Chamber for Animals.]
The flask _E_ is a 300 cc. Erlenmeyer flask, with a ground glass
stopper. The liquid to be tested is placed in this flask together
with a sufficient quantity of glass wool to prevent splashing and the
carrying over mechanically of droplets of the liquid. Air is passed
through _A_ and _C_ (calcium chloride drying tubes) and the rate
measured by the flow meter _D_. The air and gas are mixed in _F_ before
passing into the chamber _G_. This chamber is made of plate glass, is
of about 100 liters capacity, and is air-tight. The entire flow of air
and gas through the box, kept constant at 250 liters per minute, is
measured at _H_. The gas is removed through _K_, which is filled with
charcoal and soda-lime, in order that little gas may pass into the pump.
By weighing the flask _E_, and its contents before and after passing
air through it, and knowing the total volume of the mixture passing
through the chamber during the same period, the concentration of the
substance can readily be calculated. This concentration, as determined
by the “loss in weight” method, can be checked by chemical analysis
(samples taken at _M_—_M_). The method has been found to give accurate
values.
The concentration in the chamber reaches its constant level within 30
to 40 seconds after the apparatus is started.
With the flow of 250 liters per minute, the difficulties mentioned
above are reduced to a point where they are practically negligible.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account