[Illustration:
_By permission of_] [_C. H. F. Muller._
FIG. 41.--Diagram showing parts of X-Ray Tube.]
An induction coil is generally used to supply the high-tension
electricity required for the production of the Röntgen rays. For
amateur or experimental purposes a coil giving continuous 4-inch or
even 3-inch sparks will do, but for medical work, in which it is
necessary to take radiographs with very short exposures, coils giving
sparks of 10, 12, or more inches in length are employed. An electrical
influence machine, such as the Wimshurst, may be used instead of an
induction coil. Very powerful machines with several pairs of plates
of large diameter, and driven by an electric motor, are in regular
use for X-ray work in the United States, but in this country they are
used only to a very small extent. A Wimshurst machine is particularly
suitable for amateur work. If a screen is to be used for viewing bones
through the flesh a fairly large machine is required, but for screen
examination of such objects as coins in a box, or spectacles in a
case, and for taking radiographs of these and other similar objects, a
machine giving a fairly rapid succession of sparks as short as 2 inches
can be used. Of course the exposure required for taking radiographs
with a machine as small as this are very long, but as the objects are
inanimate this does not matter very much.
For amateur X-ray work the arrangement of the apparatus is simple.
The tube is held in the required position by means of a wooden clamp
attached to a stand in such a way that it is easily adjustable.
Insulated wires are led from the coil or from the Wimshurst machine
to the tube, the positive wire being connected to the anode, and the
negative wire to the cathode. With a small Wimshurst machine light
brass chains may be used instead of wires, and these have the advantage
of being easier to manipulate. For medical purposes the arrangements
are more complicated, and generally a special room is set apart for
X-ray work.
If the connexions have been made correctly, then on starting the coil
or the machine the tube lights up. The bulb appears to be sharply
divided into two parts, the part in front of the anti-cathode glowing
with a beautiful greenish-yellow light, while the part behind the
anti-cathode is dark, except for lighter patches close to the anode.
The Röntgen rays are now being produced. The illumination is not steady
like that of an electric lamp, but it consists of a series of flickers,
which, with powerful apparatus, follow one another so rapidly as to
give the impression of continuity. If the connexions are wrong, so that
the negative wire goes to the anode instead of to the cathode, the bulb
is not divided in this way, but has patches of light almost all over.
As soon as this appearance is seen the apparatus must be stopped and
the connexions reversed, for the tube is quickly damaged by passing the
discharge through it in the wrong direction.