On the other hand, if his dynamo was over-compounded 25 per cent--that
is, if it gained 28 volts from no load to full load, the system would
be perfect. In this case, the dynamo would be operated at 110 volts
pressure at the switchboard with no load. At full load the voltmeter
would indicate 110 plus 26, or 136 volts. The one or two lights burned
at the power plant would be subject to a severe strain; but the 50 or
100 lights burned at the house and barn would burn at constant
voltage, which is very economical for lamps.
The task of over-compounding a dynamo can be done by any trained
electrician. The farmer himself, if he progresses far enough in his
study of electricity, can do it. It is necessary to remove the top or
"series" winding from the field coils. Count the number of turns of
this wire to each spool. Then procure some identical wire in town and
begin experimenting. Say you found four turns of field wire to each
spool. Now wind on five, or six, being careful to wind it in the same
direction as the coils you removed and connect it in the same way. If
this additional number of turns does not raise the voltage enough, in
actual practice, when the dynamo is running from no load to full load,
add another turn or two. With patience, the task can be done by any
careful mechanic. The danger is in not winding the coils the same way
as before, and getting the connections wrong. To prevent this mistake,
make a chart of the "series" coils as you take them off.
To make the task of over-compounding your own dynamo even more simple,
write to the manufacturers, giving style and factory number of your
machine. Tell them how much voltage rise you wish to secure, and ask
them how many turns of "series" wire should be wound on each spool in
place of the old "series" coil. They could tell you exactly, since
they have mathematical diagrams of each machine they make.
Avoid overloading an over-compounded machine. Since its voltage is
raised automatically, its output in watts is increased a similar
amount at the switchboard, and, for a given resistance, its output in
amperes would be increased the same amount, as can be ascertained by
applying Ohm's Law. Your ammeter is the best guide. Your machine is
built to stand a certain number of amperes, and this should not be
exceeded in general practice.
CHAPTER VIII
WIRING THE HOUSE
The insurance code--Different kinds of wiring described--Wooden
moulding cheap and effective--The distributing panel--Branch
circuits--Protecting the circuits--The use of porcelain tubes and
other insulating devices--Putting up chandeliers and wall
brackets--"Multiple" connections--How to connect a wall
switch--Special wiring required for heat and power circuits--Knob
and cleat wiring, its advantages and drawbacks.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account