Electricity for the farm: Light, heat and power by inexpensive methods from the water wheel or farm engineAnderson, Frederick Irving
Science
Electricity for the farm: Light, heat and power by inexpensive methods from the water wheel or farm engine
Anderson, Frederick Irving
Electricity in agriculture
If one plans using electricity for heavy-duty stoves, such as ranges
and radiators, it is necessary to install a separate heating circuit.
This is the best procedure in any event, even when the devices are all
small and suited to lamp circuits. The wire used can be determined by
referring to the table for carrying capacity, under the column headed
"rubber-covered." A stove or range drawing 40 amperes, would require a
No. 4 wire, in moulding. A good plan is to run the heating circuit
through the basement, attaching it to the rafters by means of
porcelain knobs. Branches can then be run up through the floor to
places where outlets are desired. Such a branch circuit should carry
fuses suitable to the allowed carrying capacity of the wire.
_Knob and Cleat Wiring_
Knob and cleat wiring, such as is used extensively for barns and
out-buildings, requires little explanation. The wires should not be
closer than 2-1/2 inches in open places, and a wider space is better.
The wires should be drawn taut, and supported by cleats or knobs at
least every four feet. In case of branch circuits, one wire must be
protected from the other it passes by means of a porcelain tube. It
should never be used in damp places, and should be kept clear of dust
and litter, and protected from abrasion.
[Illustration: Knob and cleat wiring]
Knob and tube wiring is frequently used in houses, being concealed
between walls or flooring. In this case, the separate wires are
stretched on adjoining beams or rafters, and porcelain tubes are used,
in passing through cross beams. For a ceiling or wall outlet, a
spliced branch is passed through the plaster by means of porcelain
tubes or flexible loom.
Wires from the house to the barn should be uniform with transmission
wires. At the point of entry to buildings they must be at least six
inches apart, and must take the form of the "drop loop" as shown in
the illustration. A double-pole entrance switch must be provided,
opening downward, with a double-pole fuse. In passing over buildings
wires must not come closer than 7 feet to flat roofs, or one foot to a
ridge roof. Feed-wires for electric motors should be determined from
the table of safe carrying capacities, and should be of liberal size.
CHAPTER IX
THE ELECTRIC PLANT AT WORK
Direct-connected generating sets--Belt drive--The
switchboard--Governors and voltage regulators--Methods of achieving
constant pressure at all loads: Over-compounding the dynamo; A
system of resistances; (A home-made electric radiator); Regulating
voltage by means of the rheostat--Automatic devices--Putting the
plant in operation.
Public-domain text, read in full here on John Shaqi.