The locomotive boiler consists of a cylindrical barrel attached to a
portion containing the fire-box, which is nearly rectangular both in
horizontal and vertical section. The fire-box sides are stayed to the
fire-box shell by numerous stays about 1 in. in diameter, usually
pitched 4 in. apart both vertically and horizontally. The top of the
fire-box in small boilers is stayed by means of girder stays running
longitudinally and supported at the ends upon the tube plate and the
opposite fire-box plate. In some boilers the girders are partly
supported by slings from the crown of the boiler. In larger boilers
the crown of the boiler above the fire-box is made flat and the
fire-box crown is supported by vertical stays connecting it with the
shell crown. Provision is generally made for the expansion of the tube
plate, which is of copper, by allowing the two or three cross rows of
stays nearest the tube plate to have freedom of motion upwards but not
downwards. The ordinary tubes are usually 1-3/4 in. diameter. The
fire-bars are generally, though not always, made to slope downwards
away from the fire door, and just below the lowest tubes a fire-bridge
or baffle is fitted, extending about half-way from the tube plate to
the fire-door side of the fire-box. In some cases water-tubes are
fitted, extending right across the fire-box. In a boiler for the
London & South-Western Railway Co., having a grate area of 31.5 sq.
ft. and a total heating surface of 2727 sq. ft., there are 112
water-tubes each 2-3/4 in. diameter. These are arranged in two
clusters, each containing 56, one set being placed above the
fire-bridge, and the other set nearer the fire-door end of the boiler.
The water-tubes are of seamless steel, and are expanded into the
fire-box side plates. In way of these tubes the outer shell side
plates are supported by stay bars passing right through the
water-tubes. The usual pressure of locomotive boilers is about 175
lb. to 200 lb. per sq. in.
[Illustration: FIG. 9.]
A good example of an express locomotive boiler is shown in fig. 10. In
this case the grate area is 30.9 sq. ft. and the heating surface 2500
sq. ft. The barrel is 5 ft. 6 in. diameter, 16 ft. long between tube
plates. The fire-box crown is stayed by vertical stays extending to
the shell crown, except for the three rows of stays nearest the tube
plates. These are supported by cross girders resting upon brackets
secured to the outer shell.
[Illustration: FIG. 10.--Express Locomotive Boiler, with widened
fire-box (Great Northern Railway, England).]