_Corrosion._--When chemicals of any kind are used to soften or purify
feed-water it is essential that neither they nor the products they form
should have a corrosive effect upon the boiler-plates, &c. Much of the
corrosion which occasionally occurs has been traced to the action of the
oxygen of the air which enters the boiler in solution in the feed-water,
and the best practice now provides for the delivery of the feed into the
boiler at such positions that the air evolved from it as it becomes
heated passes direct to the steam space without having an opportunity of
becoming disengaged upon the under-water surfaces of the boiler.
Where corrosion is feared it is usual to fit zinc slabs in the water
spaces of the boiler. Experience shows that it is better to make them of
rolled rather than of cast zinc, and to secure them on studs which can
be kept bright, so as to ensure a direct metallic contact between the
zinc and the boiler-plate. The function of the zinc is to set up
galvanic action; it plays the part of the negative metal, and is
dissolved while the metal of the shell is kept electro-positive. Care
must always be taken that the fragments which break off the zinc as it
wastes away cannot fall upon the heating surfaces of the boiler.
_Evaporators._--In marine boilers the waste of water which occurs from
leakages in the cycle of the evaporation in the boiler, use in the
engine, condensation in the condenser and return to the boiler as
feed-water, is made up by fresh water distilled from sea-water in
"evaporators." Of these there are many forms with different provisions
for cleaning the coils, but they are all identical in principle. They
are fed with sea-water, and means are provided for blowing out the brine
produced in them when some of the water is evaporated. The heat required
for the evaporation is obtained from live steam from the boilers, which
is admitted into coils of copper pipe. The water condensed in these
coils is returned direct to the feed-water, and the steam evaporated
from the sea-water is led either into the low-pressure receiver of the
steam-engine or into the condenser.