_Mechanical Stoking._--Most boilers are hand-fired, a system involving
much labour and frequent openings of the furnace doors, whereby large
quantities of cold air are admitted above the fires. Many systems of
mechanical stoking have been tried, but none has been found free from
objections. That most usually employed is known as the "chain-grate"
stoker. In this system, which is illustrated in fig. 13 (Woodeson
boiler), the grate consists of a wide endless chain formed of short
cast-iron bars; this passes over suitable drums at the front and back of
the boiler, by the slow rotation of which the grate travels very slowly
from front to back. The coal, which is broken small, is fed from a
hopper over the whole width of the grate, the thickness of the fire
being regulated by a door which can be raised or lowered as desired.
Thus the volatile portions of the coal are distilled at the front of the
fire, and pass over the incandescent fuel at the back end. The speed of
travel is so regulated that by the time the remaining parts of the fuel
reach the back end the combustion is nearly complete. It will be seen
that the fire becomes thinner towards the back, and too much air is
prevented from entering the thin portion by means of vanes actuated from
the front of the boiler.
_Draught._--In most boilers the draught necessary for combustion is
"natural," i.e. produced by a chimney. For marine purposes, although
"natural" draught is the more common, many boiler installations are
fitted with "forced" draught arrangements. Two distinct systems are
used. In that known as the "closed stokehold" the stokehold compartment
of the vessel is so closed that the only exit for air from it is through
the fires. Air is driven into the stokehold by means of fans which are
made so that they can maintain an air pressure in the stokehold above
that of the outside atmosphere. This is the system almost universally
adopted in war vessels, and it is used also in some fast passenger
ships. The air pressure usually adopted in large vessels is that
corresponding to a height of from 1 to 1-1/2 in. of water, whilst so much
as 4 in. is sometimes used in torpedo-boats and similar craft. This is,
of course, in addition to the chimney-draught due to the height of the
funnel. In the closed ashpit or Howden system, the stokehold is open,
and fans drive the air round a number of tubes, situated in the uptake,
through which the products of combustion pass on their way to the
chimney. The air thus becomes heated, and part of it is then delivered
into the ashpit below the fire and part into a casing round the furnace
front from which it enters the furnace above the fire. In locomotive
boilers the draught is produced by the blast or the exhaust steam. With
natural draught a combustion of about 15 to 20 lb. of coal per sq. ft.
of grate area per hour can be obtained. With forced draught much greater
rates can be maintained, ranging from 20 lb. to 35 lb. in the larger