The boiler had one defect, seen in the front view, cross-section. A
straight passage 2 inches wide was given to the gases between each pair
of tubes.
The boilers having all had a preliminary trial during the first week,
I observed the vapor arising from the exposed surface of the water in
the tank, and that this unmeasured loss of heat differed considerably
in the different boilers, and was enormously greatest on the trial of
the Allen boiler. I said nothing, but went down early on next Monday
morning and on my way bought a common tin cup about 3 inches deep and 4
inches in diameter, and secured it in one corner of the tank, immersed
to a quarter of an inch below its rim, and filled even full of water.
This was completed before the arrival of the Committee, and was at once
approved by them. I made it my business every day to note the fall
of the water level by evaporation from this cup. On the trial of the
Allen boiler only the water in the cup was all evaporated, and I had
to fill it again. The temperature of the water in the cup was always 8
degrees below that of the surrounding water. It was thus obvious that
the evaporation from the tank was greater than the fall of the level in
the cup would indicate. The Committee considered that this should be
increased as the tension of the vapors. The result was that the report
contained the following item: Units of heat carried away by evaporation
at the surface of the tank:
Root boiler 721,390.8 units
Allen boiler 1,178,404.5 „
Phleger boiler 378,371 „
Lowe boiler 692,055 „
Blanchard boiler 268,707 „
Public-domain text, read in full here on John Shaqi.