[Illustration: Figs. 648 to 650.--Wright demand indicator. This is a
device for registering the maximum ampere demand of appreciable duration
in any electrical circuit. It may be used on either direct or alternating
current circuits. The essential features and principle are as follows: A
liquid is hermetically sealed in a glass vessel consisting of two bulbs
connected by a "U" tube, and a central tube called the "index" tube,
connected to the upper end of the right hand side of the "U." Around the
left hand or heating bulb, is placed a band of resistance metal, through
which the current to be measured is passed, or a definite shunted portion
of it. The heating effect of the current increases the temperature of the
left hand bulb, causing the air to expand which forces the liquid up the
right hand side of the "U" tube and into the index tube, where it remains
until the indicator is reset. The height of the liquid in the index tube
as shown by the scale, indicates the maximum current which has passed
through the indicator. It is the difference in temperature of the air in
the two bulbs which causes the flow of the liquid. Any change in external
temperature causes equal effect in both bulbs and therefore does not
affect the reading.]
[Illustration: Figs. 651 and 652.--Weston illuminated dial station
voltmeter and ammeter. The voltmeter has two indices, a pointed index for
close readings and an index called the _normal index_, which enables a
slight deviation from the normal voltage to be seen from a long distance.
The "normal index" is inside the case and terminates in a circular disc
of blackened aluminum. The disc is adjusted from the outside of the case
by hand, by means of the knurled knob seen on the front of the case, so
that it is directly below the point of normal voltage. When the indicating
index reaches the point of normal voltage, the disc of the normal index
appears in the center of the circular opening of the indicating index,
a narrow ring of white being visible, encircling the disc of the normal
index. The ammeter depends for its operation upon the fall of potential
between two points of the circuit carrying the main current, and requires
a difference of only about .05 volt to give a full scale deflection.
When a maximum deflection is secured, the current passing through the
instrument is never more than .07 ampere irrespective of the total
capacity of the instrument. A separate shunt is used which is placed
at the back of the switchboard. In many cases, a special shunt can be
dispensed with and a short section of the mains on the switchboard, or
the mains leading from the dynamo, can be used instead. On the basis of
one square inch cross section per 1,000 amperes, a length of about 5 feet
of copper conductor would be required as a shunt, in which case however,
this section of the conductor must be adjusted with precision.]
Ques. Explain the operation of the Siemen's electrodynamometer.