Traps were formerly placed at the upper end of the waste-pipe of the
sinks when this was directly connected with the drain. Of these the
Bell-trap and Antill’s trap were most common. The Bell-trap has been
described above. In the Antill-trap the trap is not removable, and the
water-seal is deeper than with a bell-trap. This trap is sometimes used
instead of a gully-trap, but is not so good.
=Efficiency of Traps.=—Eassie has said “honestly speaking, traps are
dangerous articles to deal with; they should be treated merely as
auxiliaries to a good drainage system.”
(1) The trap may have been imperfectly laid to begin with.
(2) It may be emptied by evaporation.
(3) Unless the precautions already mentioned (pages 172 to 173) are
adopted, the flushing of one trap may empty another.
(4) The water of the trap may become impregnated with foul gases, and
these then escape on the house-side of the trap. When a sewer becomes
suddenly charged with a large amount of water, as during heavy rain,
sewer-gases may force their way through the intercepting trap. With a
ventilated drain and soil-pipe these dangers are so small that they may
be ignored.
=Unsyphoning= of traps has been already mentioned. It occurs
particularly when there are several water-closets one over another,
connected with the same soil-pipe. The method of preventing it is shown
in Fig. 28.
=The Examination of Drains and Sanitary Appliances.=—This examination
will involve the detection of (_a_) any deviations from the details
of construction and ventilation of drain and soil-pipe, form of w.c.,
disconnection of waste-pipes, already insisted on; and (_b_) any defect
or leakage in any part of these.
1. _Testing of Water-closet._—The interior of the basin or pan may be
painted with a mixture of lamp-black, size and water. If the usual
flush applied immediately afterwards clears this off, the form of pan
and the flushing power are satisfactory. By removing the wood-work
around the w.c., leakage or spillings of slop-water around the w.c. can
be detected.
2. _Testing of the soil-pipe_ may be effected by one of the volatile
tests named under the next heading. To give the test a fair trial, the
upper end of the ventilating pipe should be temporarily sealed over.
3. _Testing of the drain_ cannot be efficiently carried out unless
access can be obtained to the drain near the sewer. In a properly
constructed house-drain a man-hole is provided for this purpose. Two
chief methods of testing drains and soil-pipes are in use, by smoke or
volatile agents and by water.