The plan which was adopted as the most suitable under all the
considerations of economy and security to the work, was a _Low Bridge_
to support an inverted syphon of iron pipes; and the design of it was
as follows: adjacent to the southern shore of the river there was to
be constructed an arch for the channel of the river, of 80 feet span
and springing from abutments 10 feet above high water level; this would
form a passage of 80 feet wide, and the height from high water level
to the under side of the arch at the crown would be 50 feet: south of
this arch followed three other arches on the slope of the rocky hill,
of 35, 30, and 25 feet span: south of these arches a foundation wall
was designed to continue the plane of inclination to the level of the
Aqueduct. From the large arch to the northern shore of the river an
embankment of stone was designed for the support of the pipes, and from
this wall the table land on the northern shore and the slope of the
northern side of the valley, would be excavated to a form to give the
proper position to the pipes descending from the Aqueduct. The lowest
level of the top of this stone embankment was designed to be 4 feet
above flood tide. Suitable parapet walls were designed to be built
along the sides of the embankment to sustain a covering of earth over
the pipes. With the form which was given to this _inverted syphon_,
four pipes, each of 3 feet interior diameter, were found to give a
discharge of water equal to that of the Aqueduct of masonry on the
established inclination.
In accordance with this plan of the _Low Bridge_ the work for
crossing the River was put under contract and some progress made in
its execution, when a law was passed by the Legislature of the State
requiring, instead of this, a structure, the arches of which should
be (over the channel of the river) at least 80 feet span and having a
distance of 100 feet from the level of high water to the under side of
the crown; or to go under the channel of the river by a structure which
should not rise above the bed, and that would leave the present channel
unobstructed. At this time when the work was going on vigorously,
they were compelled to abandon the plan which had been adopted, and
devise one which would comply with the requirements of the law of the
Legislature. A comparison was instituted between the plan of a tunnel
under the bed of the river and that of a bridge of masonry at the
required height above the river.
The tunnel would be at least 300 feet long and the top of the masonry
forming it, would be 18 feet below high water level. In this tunnel the
iron pipes would pass under the River and would be protected from the
salt water.
[Illustration: XVIII
_F. B. Tower._ _W. Bennett. sc._
CROTON AQUEDUCT AT YONKERS.]