_Ducts._--The main duct should be of metal (steel, sheet-iron, or
zinc); it should be circular in shape, have as straight and short a
course as possible, and be tapered in such manner that the area of
cross-section at any point shall equal the combined areas of all the
branch pipes which have entered it at that point (Fig. 3). Proper
dimensions must be studied in relation to the size of the fan and the
work to be done. Wooden ducts, unless chosen for specific reasons,
such as the presence of acid in the fumes to be removed, are very
unsatisfactory, as it is difficult to maintain them in an air-tight
condition or to make branch pipes enter with rounded junctions. Where
several branch ducts enter a main duct, situation of the fan midway
between them has advantage, not only in saving metal in piping, but
also in causing the distance of the fan from the farthest branch
duct to be only half what it would be were the fan placed at the end
of the system (see Fig. 7, p. 217). Further, the sectional area of
the two collecting ducts will be less than that of one main duct, and
greater uniformity of flow thereby secured. Where the two ducts join
up into the single duct of the fan, the bends must be easy; otherwise
the draughts would collide and neutralize one another. Branch ducts,
if they cannot be made tangential to a rounded curve, should enter
the main duct at an angle of 30 degrees, as by so doing equalization
of the draught at different openings is made fairly uniform. The very
common defect of a right-angle joint diminishes the draught by nearly
one-half. Branch ducts should never be made to enter a main duct on the
outer side of a bend, because at this point the pressure of the current
of air inside the duct is increased. They should join up on the inside
of a bend, where the pressure is reduced.