Lightning conductors
The apparatus is as simple as it may be useful, and the more so, of
course, the thicker the mass of charcoal in which it is embedded. But
it may be doubted whether it is sufficient to make ‘good earth’ under
all circumstances. Perhaps it will do so in ninety-nine cases and fail
in the hundredth. The amount of electric force discharged in ordinary
thunderstorms does not seem to vary much, and, according to all
observations, such an artificial connection as this of the charcoal bed
is sufficient to disperse it safely beneath the surface. But now and
then there come storms of extraordinary violence, or, in other words,
extraordinary accumulations of atmosphere electricity, which demand
precautions such as are not fulfilled by the subterranean harrow,
however thickly embedded in charcoal, or, as oftener done, in gas coke
or cinders. It is certain that there have been cases in which buildings
with otherwise excellent conductors, but provided with such an
artificial earth connection, have been damaged by lightning. However,
it may be stated, as the net result of all observations and known facts
upon the subject, that small private houses can be well protected by
this means against lightning, but that the system cannot be recommended
as absolutely safe for large edifices and public buildings.
To protect any structure of great extent, it is absolutely necessary to
bring the conductor, or conductors, deep enough into the earth to reach
water. It is all the more indispensable with modern buildings, as they
contain large masses of metal, not only in gas and water-pipes, but
often in staircases and iron columns, towards which the electric force
has the strongest tendency to direct itself unless drawn to the earth
by an immediate and unfailing connection with the great sheet of water
below its surface. It is considered by German electricians that there
is no necessity, if a large edifice has a number of conductors, to let
each have a separate earth connection; it is quite sufficient to bring
them all into one, provided only that this is absolutely perfect at all
seasons and under all circumstances. Fig. 49 will show how this can be
done.
[Illustration: Fig. 49.]
It will be seen that for the protection of this edifice there are six
conductors, with four elevated points marked A, B, C and _c_. Two of
these points, A and C, expand from the roof to the ground into double
conductors, so as to protect the sides of the building against possible
lateral discharges of lightning, and all the six conductors meet a
little below the surface in the earth connection prepared for them. To
form this one connection, either by digging or boring, may sometimes
be costly, but whether the expenses be more or less, the protection
against lightning thus effected will be so absolute as to be invaluable.
In a similar manner as the large edifice, with its many gables, a
church may be fitted with lightning conductors. Fig. 50 scarcely needs
much explanation.