When the question of laying an Atlantic cable began to be debated in the
middle of the nineteenth century, Professor Thomson undertook the
discussion of the theory of signalling through such a cable. It was not
generally understood by practical telegraphists that the conditions of
working would be very different from those to which they were accustomed
on land lines, and that the instruments employed on such lines would be
useless for a cable. Such a cable consists of a copper conductor
separated from the sea-water by a coating of gutta-percha; it forms an
elongated Leyden jar of very great capacity, which, when a battery is
connected to one end of the conducting core, is gradually charged up,
first at that end, and later and later at greater distances from it, and
then is gradually discharged again when the battery is withdrawn and the
end of the conductor connected to earth. Here, again, an application of
Fourier's analysis solved the problem, which, with certain
modifications, and on the supposition that the working is slow, is
essentially the same problem as the diffusion of heat along a
conducting bar, or the diffusion of a salt solution along a column of
water. The signals are retarded (and this was one of the results of the
investigation) in such a manner "that the time required to reach a
stated fraction of the maximum strength of current at the remote end,"
when a given potential difference is applied at the other, or home end,
is proportional to the product of the capacity and resistance of the
cable, each taken per unit of the length, and also proportional to the
square of the length of cable. In other words, the retardation is
proportional to the product of the resistance of the copper conductor
and the total capacity of the cable. This gave a practical rule of great
importance for guidance in the manufacture of submarine cables. The
conductor should have the highest conductivity obtainable, and should
therefore be of pure copper; the insulating covering should, while
forming a nearly absolutely non-conducting sheath, have as low a
specific inductive capacity as possible. The first of these conditions
ran counter to some views that had been put forward, to the effect that
it was only necessary to have the internal conductor highly conducting
on its surface; and some controversy on the subject ensued. The inverse
square law, as it was called, was vehemently called in question, from a
mistaken interpretation of some experiments that were made to test it.
For if the potential at the home end be regularly altered, according to
the simple harmonic law, so that the number of periods of oscillation in
a second is n, the changes of potential are propagated with velocity
2√(πn⧸cr), where c and r are the capacity and resistance of the cable,
each taken per unit length. In this case, for a long cable, there is a
velocity of propagation independent of the length; and this fact seems
to have misled the experimenters.