The overcharge should be prolonged until all the cells gas freely and
until no rise in the specific gravity and voltage of the pilot cell is
shown for five successive 15-minute readings.
Just before the overcharge the cells should be carefully examined to
see that they are free from short circuits. If any short circuits are
found they should be removed with a stick or a piece of hard rubber; do
not use metal.
As the temperature affects the specific gravity this must be considered
and correction made for any change of temperature. The temperature
correction is one point (0.001 sp. g.) for 3 degrees change in
temperature. For instance, electrolyte, which is 1.210 at 70°, will be
1.213 at 61° and 1.207 at 79°.
=Inspection.=—In order that the battery may continue in the best
condition it is essential that specific gravity and voltage readings be
taken on all cells in the battery at least once a week; the specific
gravity readings on the day before the overcharge and the voltage
reading near the end; the voltage readings must always be taken when
the current is flowing, open circuit readings being of no value. Also,
at the end of each charge it should be noted that all of the cells are
gassing moderately and at the end of the overcharge very freely.
=Unevenness of cells; cause and remedy.=—If any of the cells should
read low at either time and do not gas freely with the others at the
end of charge, examine them carefully for pieces of scale or foreign
matter which may have lodged between the plates. If any are noted,
remove them by pushing down into the bottom of the jar with a strip of
wood. Never use metal of any kind for this purpose.
If, after the cause of the trouble has been removed, the readings do
not come up at the end of the overcharge, then the cell must be cut out
of circuit on the discharge, to be cut in again just before beginning
the next charge, during which it should come up all right.
Impurities in the electrolyte will cause a cell to work irregularly
and the plates to deteriorate. Should it be known that any impurity
has gotten into the electrolyte, steps should be taken to remove it at
once. The solution should be replaced with new immediately, thoroughly
flushing the cell with water before putting in the new electrolyte.
The change should be made when the battery is discharged, for the
impurities will be in the electrolyte when the battery is discharged.
Immediately after the change the cell should be charged. If in doubt
as to whether the electrolyte contains impurities, a half-pint sample,
taken at the end of discharge, should be submitted for test.