=193. Sifting with Water.=—In soils where the particles adhere firmly
the sifting should be done with the help of water. In such cases the
soil is gently rubbed with a soft steple or the finger in water. It is
then transferred to the sieve or battery of sieves which are held in the
water, and rubbed through each of the sieves successively until the
separation is complete. After the filtrate has stood for a few minutes
the supernatant muddy liquor is poured off, the part remaining on the
sieve is added to it and the process repeated until only clean particles
larger than 0.5 millimeter are left on the sieve. These particles can be
dried and weighed and entered on the note book as sand. The filtrate
should be evaporated to dryness at a gentle temperature and when
sufficiently dry be rubbed up into a homogeneous mass by a rubber
pestle.
The sieve recommended by the Association of Official Agricultural
Chemists[129] for the preparation of fine earth for chemical analysis
has circular openings ¹⁄₂₅ inch (one millimeter) in diameter.
Wahnschaffe[130] directs that a sieve of two millimeters mesh be used in
preparing the sample for silt analysis and that the residue after the
silt analysis is finished, which has not been carried over by a velocity
of twenty-five millimeters per second, be separated in sieves of one
millimeter and 0.5 millimeter meshes respectively.
Hilgard objects to leaving this coarse material in the sample during the
process of churn elutriation on account of the attrition which it exerts
and therefore directs that it be separated by sieve analysis before the
elutriation begins.
=194. Method of the German Experiment Stations.=[131]—In the method
recommended for the German Agricultural Stations an attempt is made to
secure even a finer sieve separation than that already mentioned.
Sieves having the following dimensions are employed; sieve No. 1, square
meshes 0.09 millimeter in size, diagonal measure 0.11 millimeter; sieve
No. 2, square meshes 0.14 to 0.17 millimeter in diameter, diagonal
measure 0.22 to 0.24 millimeter; sieve No. 3, square meshes 0.35 to 0.39
millimeter in diameter, diagonal measure 0.45 to 0.50 millimeter;
finally a series of sieves one, two and three millimeters circular
perforations.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account