=60. Construction of electrometers.= As the quadrant electrometer has
gained the reputation of being a difficult and uncertain instrument for
accurate measurements of current, it may be of value to give some
particular details in regard to the best method of construction and
insulation. In most of the older types of quadrant electrometers the
needle system was made unnecessarily heavy. In consequence of this, if a
sensibility of the order of 100 mms. deflection for 1 volt was required,
it was necessary to charge the Leyden jar connected to the needle to a
fairly high potential. This at once introduced difficulties, for at a
high potential it is not easy to insulate the Leyden jar satisfactorily,
or to charge it to the same potential from day to day. This drawback is
to a large extent avoided in the White pattern of the Kelvin
electrometer, which is provided with a replenisher and attracted disc
for keeping the potential of the needle at a definite value. If
sufficient trouble is taken in insulating and setting up this type of
electrometer, it proves a very useful instrument of moderate
sensibility, and will continue in good working order for a year or more
without much attention.
Simpler types of electrometer of greater sensibility can however be
readily constructed to give accurate results. The old type of quadrant
electrometer, to be found in every laboratory, can readily be modified
to prove a useful and trustworthy instrument. A light needle can be made
of thin aluminium, of silvered paper or of a thin plate of mica, covered
with gold-leaf to make it conducting. The aluminium wire and mirror
attached should be made as light as possible. The needle should be
supported either by a fine quartz fibre or a long bifilar suspension of
silk. A very fine phosphor bronze wire of some length is also very
satisfactory. A magnetic control is not very suitable, as it is
disturbed by coils or dynamos working in the neighbourhood. In addition,
the zero point of the needle is not as steady as with the quartz or
bifilar suspension.
When an electrometer is used to measure a current by noting the rate of
movement of the needle, it is essential that the needle should be damped
sufficiently to give a uniform motion of the spot of light over the
scale. The damping requires fairly accurate adjustment. If it is too
little, the needle has an oscillatory movement superimposed on the
steady motion; if it is too great, it moves too sluggishly from rest and
takes some time to attain a state of uniform motion. With a light
needle, very little, if any, extra damping is required. A light platinum
wire with a single loop dipping in sulphuric acid is generally
sufficient for the purpose.