Records of Steam Boiler ExplosionsMarten, Edward Bindon
History
Records of Steam Boiler Explosions
Marten, Edward Bindon
Steam-boiler explosions
Chemical boiler, Plain cylinder, 12ft. 6in. high, 4ft. 6in. diameter,
3/8 inch plates, with cast-iron hemispherical ends with manhole in
each. The pressure of 34 lbs. was obtained from another boiler. The
bottom end gave way where the casting was defective, a piece was blown
out, and the reaction of the issuing contents projected the boiler
through the roof, through which it again descended and did much damage.
_No. 44. Cardiff. (Fig. 26.) September 1st. 2 killed, 2 injured._
[Illustration: _Fig. 26._]
Marine. Multitubular, 6ft. long, 6ft. diameter, 60 lbs. pressure. The
under side of fire box gave way at the front rivets, the heads of which
were corroded, and a tongue of plate was torn upwards, allowing the
contents to issue so violently, that those near were carried overboard
and drowned.
_No. 45. Gresley. (Fig. 27.) September 2nd. 7 injured._
[Illustration: _Fig. 27._]
One of six, 2 years old. Plain cylinder, 40ft. long, 5ft. diameter, 3/8
inch plates, 50 lbs. pressure. This case was peculiar, as the back part
of the boiler was found a long way to the front, and the front end in
the rear. An accumulation of scale caused pocket to form, and a hole
to burn through the bottom over the grate, allowing the contents to
issue so violently that the boiler was sent over end for end, when the
front end was knocked off and thrown to the rear, and the contents then
issuing more violently, the reaction sent the rest of the boiler in one
piece a great distance to the front, where it fell, and was crushed
nearly flat and broken into several fragments.
_No. 46. Cornwall. (Fig. 28.) September 16th. 4 injured._
[Illustration: _Fig. 28._]
One of two, 18 years old. Cornish, 32ft. 9in. long, 6ft. 6in. diameter.
Tube 4ft. diameter, 3/8 inch plates, 45 lbs. pressure. The tube
collapsed from end to end, dropping together like an old sack, and
cracking at the edges. A small piece at the front end was blown out.
The cause was supposed to be shortness of water as there was no gauge
glass, but it was far more likely the weakness of so large a tube
without strengthening hoops. The pressure was doubtless more than
usual, as the engine had made a temporary stand. A similar collapse
took place in the next boiler in December, 1869, and is described as
No. 57 in the "records" of that year.
_No. 47. Hull. (Fig. 29.) September 22nd. 2 injured._
[Illustration: _Fig. 29._]
Vertical, with fire box of peculiar corrugated construction, 7ft. 6in.
high, 3ft. diameter, 50 lbs. pressure. Gave way round the bottom of
fire box where much corroded and rent open, and the reaction of the
issuing contents carried the whole boiler to a considerable distance.
The pressure gauge had been removed, and the safety valve did not act
freely, and the pressure accumulated to more than the boiler could bear.
_No. 48. Grindleton. (Fig. 30.) September 26th. 1 killed._
[Illustration: _Fig. 30._]