Records of Steam Boiler ExplosionsMarten, Edward Bindon
History
Records of Steam Boiler Explosions
Marten, Edward Bindon
Steam-boiler explosions
The central flue showed a slight indication of overheating, but the
construction was such that the upper portion passed through the steam
space, and was always exposed to the action of the fire, without the
protection of the contact of water. The manhole without a ring on its
edge to strengthen the plate, and held in by two clamps, which caused
additional strain when carelessly screwed up, was by far the weakest
place. The engine was standing after a short time of working, and as
the safety valve was very defective, and could be screwed down until
tight, against almost any pressure, it is most probable that the
pressure mounted much higher than usual, when the weakest part gave
way, and led to the sudden tearing up and scattering of the whole
fabric.
Faulty construction of both boiler and fittings, rendered it unable to
bear that accumulated pressure, which the safety valve ought to have
made impossible.
_No. 58. Durham. October 13th. 1 killed._
One Tube Cornish, 14ft. long, 6ft. diameter, internal flue 3ft. 3in.,
by 2ft. 10in., 3/8 inch plates, 27 lbs., standing on three saddles,
with a bearing surface of 3ft. by 4 inches.
A portion of plate 20in. by 18in., at the bottom of the boiler, was so
corroded that it was blown out, and the issuing contents scalded a man
to death.
_No. 59. Bristol. (Fig. 26.) November 1st. 7 killed._
[Illustration: _Fig. 26._]
Two Marine Boilers exploded simultaneously. They were 16ft. long,
6ft. 6in. diameter at the flat front ends, and somewhat less at the
hemispherical back ends. Each had two internal fireplaces, united in
one flue, which returned nearly to the front and passed up through the
steam space, and out at the top of shell into the funnel. The central
fireplaces were not circular, and the outside fireplaces and the return
flues were still more distorted, but the weakness of the shape was
somewhat compensated for by stays between the tubes, and from the tubes
to the shell. The mountings to the boiler were of the ordinary kind and
efficient.
The under sides of the shells were so deeply corroded that they were
rent longitudinally for their whole length, allowing the sides to
open out and tear away from the front ends. Each shell fell at a
considerable distance. The furnaces, with parts of the front ends
attached, fell into the water, but except one of the side flues that
was a little collapsed, they were uninjured. Small pieces of the front
ends were thrown to a great distance. The sides of the vessel were so
completely blown out that she sank.
The corrosion was no doubt caused by the leakage of the vessel, keeping
the shells of the boilers constantly wet.
_No. 60. London. (Fig. 27.) November 3rd. none injured._
[Illustration: _Fig. 27._]
Agricultural, barrel was 3ft. 9in. long, and 2ft. 6in. diameter, 70
lbs. From the internal fire-box the heat passed through a number of
1-inch tubes to the front smoke box and chimney.