Research methods in ecologyClements, Frederic E. (Frederic Edward)
Science
Research methods in ecology
Clements, Frederic E. (Frederic Edward)
Plant ecology; Plant ecology -- Methodology
=59. Instruments.= As a direct factor, humidity is intimately connected
with water-content in determining the structure and distribution of
plants. The one is in control of water loss; the other regulates water
supply. Humidity as a climatic factor undergoes greater fluctuation in
the same habitat, and the efficient difference is correspondingly
greater. Accordingly, simple instruments are less valuable than
automatic ones, since a continuous record is essential to a proper
understanding of the real influence of humidity. As is the rule,
however, the use of simple instruments, when they can be referred to an
ecographic basis, greatly extends the field which can be studied. In
investigation, both psychrometer and psychrograph have their proper
place. In the consideration of simple instruments for obtaining humidity
values, an arbitrary distinction is made between psychrometers and
hygrometers. The former consist of a wet and a dry bulb thermometer,
while the latter make use of a hygroscopic awn, hair, or other object.
_Psychrometers_
=60. Kinds.= There are three kinds of psychrometer, the sling, the cog,
and the stationary. All consist of a wet bulb and a dry bulb thermometer
set in a case; the first two are designed to be moved or whirled in the
air. The same principle is applied in each, viz., that evaporation
produces a decrease in temperature proportional to the amount of
moisture in the air. The dry bulb thermometer is an ordinary
thermometer, while the wet bulb is covered with a cloth that can be
moistened. The former indicates the normal temperature of the air, the
latter gives the reduced temperature due to evaporation. The relative
humidity of the air is ascertained by means of the proper tables, from
two terms, i. e., the air temperature and the amount of reduction shown
by the wet bulb. The sling and the cog psychrometers alone are in
general use. The stationary form has been found to be unreliable,
because the moisture, as it evaporates from the wet bulb, is not
removed, and, in consequence, hinders evaporation to the proper degree.
[Illustration: Fig. 5. Sling psychrometer.]