=94. Air thermometers.= The accurate measurement of temperature requires
standard thermometers. Reasonably accurate instruments may be
standardized by determining their error, but they are extremely
unsatisfactory in practice, since they result in a serious waste of
time. Accurate thermometers which read to the degree are entirely
serviceable as a rule, but instruments which read to a fraction of a
degree are often very much to be desired. The writer has found the
“cylindrical bulb thermometer, Centigrade scale” of H. J. Green, to be
an exceedingly satisfactory instrument. The best numbers for general use
are 247 and 251, which read from –15° to 50° C. and are graduated
in .2°. They are respectively 9 and 12 inches long, and cost $2.75 and
$3.50. These instruments are delicate and require careful handling, but
even in class work this has proved to be an advantage rather than
otherwise. In making readings of air temperatures with such
thermometers, constant precautions must be taken to expose the bulb
directly to the wind and to keep it away from the hand and person.
=95. Soil thermometers.= The thermometer described above has been used
extensively for soil temperatures. The determination of the latter is
conveniently combined with the taking of soil samples, by using the hole
for a temperature reading. When carefully covered, these holes can be
used from day to day throughout the season without appreciable error,
even in gravel soils. Repeated tests of this have been made by
simultaneous readings in permanent and newly made holes, and the results
have always been the same. It has even been found that the error is
usually less than 1 degree when the hole is left uncovered, if it is
more than 9 inches deep. A slight source of error lies in the fact that
the thermometer must be raised to make the reading. With a little
practice, however, the top of the column of mercury may be raised to the
surface and read before the change of temperature can react upon it.
This is especially important in very moist or wet soils where the bulb
becomes coated with a film of moisture. This evaporates when the bulb is
brought into the air, and after a moment or two the mercury slowly
falls.
[Illustration: Fig. 16. Soil thermometer]