106. RICE’S EXPERIMENT. APPARATUS FOR OBTAINING X-RAYS. § 109, 114, 131,
137. TUBE ENERGIZED BY A WIMSHURST MACHINE. _Elect. Eng._, N.Y., Apr.
22, p. 410.—Roentgen had always employed the induction coil. As to those
who first excited the discharge tube by the Holtz or Wimshurst machine
or generators of like nature, it is not certain; but, according to
public records, they were independently Prof. M. I. Pupin, of Columbia
College, and Dr. William J. Morton, of New York. See _Electricity_,
N.Y., Feb. 19, ’96. The accompanying cut marked “Rice’s Experiment, Fig.
1,” is a diagram representing the several elements of the apparatus,
while “Rice’s Experiment, Fig. 2,” shows what kind of a sciagraph can be
obtained by means of a Wimshurst machine. § 101, at centre. The details
of the apparatus as employed by Mr. E. Wilbur Rice, Jr., Technical
Director of the General Electric Co., were as follows: A Wimshurst
machine, having a glass plate 16 inches diameter, coupled up with the
usual small Leyden jars, spark under best conditions of atmosphere,
etc., 4 inches. “The usual method of taking pictures with such a machine
is to connect the interior coatings of the two jars, respectively, to
the positive and negative conductors of the machine, the terminals of
the discharge tube being connected between the external coatings of the
Leyden jars. In this condition, the disruptive discharge of the Leyden
jars passes through the tube and across the balls upon the terminals of
the conductors of the machine, the length of spark being regulated by
separating the balls in the usual way.” Later, he found that by omitting
the Leyden jars, the generation of the X-rays was practically
non-intermittent. He therefore connected the terminals of the discharge
tube directly to those of the Wimshurst machine as indicated in “Rice’s
Experiment, Fig. 1,” which also illustrates the details in the carrying
out of the experiment for obtaining the picture, Fig. 2, of the purse
containing the coins and a key. The principal feature was the
introduction of a lead diaphragm containing a small central opening 7-8
inch diameter opposite the fluorescent spot. Sciagraphs taken thus
required a little more time, about 60 minutes, while without the
diaphragm, the time could be shortened to about 30 minutes, but the
shadows were not so clear in the latter case. The figures are on p. 100.
[Illustration:
RICE’S EXPERIMENT. FIG. 1, § 106, p. 99.
Diagram.
]
[Illustration:
RICE’S EXPERIMENT. FIG. 2, § 106, p. 99.
Taken with the above apparatus.
]
107. SOURCE OF X-RAYS TESTED BY PROPAGATION THROUGH A SMALL HOLE.—This
would illustrate not only that the fluorescent spot is the source of
X-rays, but also that a very small portion comes from other parts that
are probably bombarded by stray cathode rays (due to irregular surface
of cathode § 57, or by reflected X-rays or cathode rays.