Rate of Flow | | | | |
in Gallons | | | | |
Per Day | 1/2" Pipe | 5/8" Pipe | 3/4" Pipe | 1" Pipe | 1-1/4" Pipe
-------------+-----------+-----------+-----------+---------+-------------
3500 | 13.95 | 4.81 | 2.35 | 0.66 | 0.25
7000 | 47.17 | 17.30 | 7.45 | 2.04 | 0.74
14000 | 163.09 | 57.8 | 25.00 | 6.64 | 2.41
========================================================================
The table shows how much additional elevation is needed over the 20 feet
already referred to. For example, suppose it is decided that a rate of 1
quart in 10 seconds is to be maintained from three faucets or a rate of
7000 gallons per day. Suppose that a pond 4000 feet away is found to be
50 feet above the highest faucet in the house, and it is a question what
size pipe ought to be used. By the table a 1-inch pipe loses 2.6 feet
per 100 feet or 104 feet in the 4000 feet, an impossible amount when
only 50 feet are available, although the size would be entirely proper
if the difference of level was 124 feet or anything greater. A
1-1/4-inch pipe, however, loses only 0.74 foot in 100 or 39 feet per
mile, so that the 1-1/4-inch pipe would be necessary, although that size
would answer even if the pond were a mile and a quarter away.
When water from a well is pumped to an elevated tank there is the same
necessity of providing about 20 feet difference in level between the
tank and the highest fixture, but the length of pipe involved being
small, the friction losses are not great. It should be noted even here
that too small a pipe may reduce the pressure, a 1/2-inch pipe causing a
loss of 47 feet in a 100-foot pipe line. If a tower is built by the side
of the house, the distance down to the ground, across to the house, and
up to the second floor would hardly be less than 50 feet, and this is a
loss of 23-1/2 feet, which means that the tank would have to be set
higher in the air by this amount. With a 3/4-inch pipe, it should go 3.7
feet, and with a 1-inch pipe but a foot higher than the level necessary
to make the water flow out of the faucet at the rate already specified.