=60. Grease Traps.=—The presence of grease in sewers results in the
formation of incrustations which are difficult to remove and which cause
a material loss in the capacity of the sewer. The presence of oil and
gasoline has resulted in violent and destructive explosions as is
described in Chapter XII. A type of grease trap used on the drains from
hotels, restaurants, or other large grease producing industries is shown
in Fig. 35. The trap is similar to a catch-basin except that it is too
small for a man to enter, and the outlet is necessarily trapped in order
to prevent the escape of grease. The details of a gasoline and oil
separator approved by the New York City Fire Department are shown in
Fig. 36.[36]
[Illustration:
FIG. 36.—Gasoline and Oil Separator.
]
=61. Flush-Tanks.=—These are devices to hold water used in flushing
sewers. They are required only on sanitary and combined sewers. Their
use tends to prevent the clogging of sewers laid on flat grades and
permits flatter grades in construction than could otherwise be adopted.
Flush-tanks may be operated either by hand or automatically. Automatic
operation is more common than hand operation. The hand-operated tanks
are similar to manholes so arranged that the inlet and outlet sewers can
be plugged while the manhole or tank is being filled with water either
from a hose or a special service connection. When sufficient water has
been accumulated the outlet is opened and the sewer is flushed by the
rush of water. A sluice gate, flap valve, or a specially fitted board is
sufficient to fit over the mouth of the inlet and outlet during the
filling of the tank. Such an arrangement has the advantage of being
cheap, simple, and satisfactory, though somewhat crude. In some cases
water is run into the tank at the same rate that it is discharged
through the open outlet, maintaining a depth of 4 or 5 feet in the tank
until the water passing the manhole below runs clean. The volume of
water required by this method is large. Flushing water under a
relatively high head is sometimes obtained by the use of tank wagons
which are quickly emptied into the sewer through a canvas pipe dropped
down a manhole. In all such cases if not well constructed the manhole is
subject to caving due to the rush of water around the outlet.
Precautions should be taken to minimize this danger by limiting the
depth of water which may be accumulated. This can be done by
constructing an overflow at a height of 4 or 5 feet above the bottom of
the manhole, discharging into the sewer through an outside drain.