In the design of an overflow weir by this formula the height of the weir
above the invert of the sewer and the flow over the weir should be
determined arbitrarily. The height should be subtracted from the
computed depth of water above the weir to determine the value of
_h__{1}. The difference between the flow over the weir and the flow
above the weir will represent the rate of flow in the sewer below the
weir. The value of _h__{2} can then be computed as the difference in the
depth of flow below the weir and the height of the weir above the
invert. The value of _V_ is computed from Kutter’s formula. The length
of the weir is determined by substituting these values in the formula.
=64. Junctions.=—At the junction of two or more sewers the elevation of
the inverts should be such that the normal flow lines are at the same
elevation in all sewers. The sewers should approach the junction on a
steep grade to prevent sewage backing up in one when the other is
flowing full. The velocity of flow at the junction should not be
decreased and turbulence should be avoided in order to prevent
sedimentation and loss of head. The junction should be effected on
smooth easy curves with radii at least five times the diameter of the
sewer where possible. Curves with short radii cause backing up of sewage
thus reducing the capacity of the sewers.
The terms bellmouth or trumpet arch are sometimes applied to the
junction of sewers large enough to be entered by a man. In small sewers
the Y branches and special junctions are manufactured so that the center
lines of the pipes intersect, and the junctions of mains and laterals
are made in manholes. In the construction of a bellmouth the arch is
carried over all the sewers. A manhole should be constructed at these
junctions as clogging frequently occurs there, due to swirling and back
eddies which cannot be avoided.
=65. Outlets.=—The outlets to a sewerage system discharging into a
swiftly running stream must be protected against wash and floating
debris. In a stream or other body of water subject to wide variations in
elevation the backing up of the sewage during high water should be
avoided. Where tidal flats or low ground about the outlet may be
alternately submerged and uncovered the discharge should always be into
swiftly running water. In quiescent bodies of water such as lakes and
harbors, and in rivers where the dilution is low, and in many other
cases, the sewer outlet should be submerged.
[Illustration:
FIG. 46.—Tide Gate.
]