Ventilation in tunnels working under air pressure is supplied from the
compressors, and the air is delivered near the face of the heading,
except that being used in the locks. In tunnels using air drills, the
air for the drills is conducted through a separate pipe as it is not
economical to compress the ventilating air to the pressure necessary to
operate the drills.
=170. Compressed Air.=—Compressed air is used in tunnel work to prevent
the entrance of water into the tunnel and to keep the work dry. The
pressure of air used is closely that of the pressure of the ground water
but in a large tunnel or a tunnel with a weak roof the pressure may be
somewhat lower on account of the danger of blowing through the roof. It
is evident that the water pressure cannot be balanced at the top and the
bottom of the tunnel. To balance it at the bottom makes a blow out near
the top more probable. To balance the pressure at the top may leave the
bottom wet. Judgment and care must be exercised during construction and
if the pressure is balanced at or near the bottom the roof must be
carefully guarded by grouting and puddling with clay, or the surface,
particularly if under water, may be covered with a clay bank. If the
cavities in the tunnel lining are large, sawdust can be mixed with the
grout to advantage, the mixture being pumped through holes in the roof
by hand or power operated force pumps. “Blows” must be carefully guarded
against as they endanger the lives of the workmen and threaten the loss
of the tunnel. The pressure and volume of air supplied for some large
subaqueous tunnels is shown in Table 61.
Labor under compressed air is arduous and dangerous with the best of
safeguards.[96] Pressure more than about 43 pounds per square inch
cannot be used and at this high pressure men cannot work more than four
hours at a time. Little or no distress is noted at pressures less than
15 pounds.
TABLE 61
VOLUME AND PRESSURE OF COMPRESSED AIR IN TUNNELS