A hose should be attached to the separator outlet leading to a vessel of
water on a platform scale graduated to 1/100 of a pound. The steam
outlet should be connected to another vessel of water resting on a
second scale. In each case, the weight of each vessel and its contents
should be noted. When ready for an observation, the instrument should be
blown out thoroughly so that there will be no water within the
separator. The separator drip should then be closed and the steam hose
inserted into the vessel of water at the same instant. When the
separator has accumulated a sufficient quantity of water, the valve of
the instrument should be closed and the hose removed from the vessel of
water. The separator should be emptied into the vessel on its scale. The
final weight of each vessel and its contents are to be noted and the
differences between the final and original weights will represent the
weight of moisture collected by the separator and the weight of steam
from which the moisture has been taken. The proportion of moisture can
then be calculated from the following formula:
100 w
x = ----- (7)
W - w
Where x = per cent moisture in steam,
W = weight of steam condensed,
w = weight of moisture as taken out by the separating
calorimeter.
Sampling Nipple--The principle source of error in steam calorimeter
determinations is the failure to obtain an average sample of the steam
delivered by the boiler and it is extremely doubtful whether such a
sample is ever obtained. The two governing features in the obtaining of
such a sample are the type of sampling nozzle used and its location.
The American Society of Mechanical Engineers recommends a sampling
nozzle made of one-half inch iron pipe closed at the inner end and the
interior portion perforated with not less than twenty one-eighth inch
holes equally distributed from end to end and preferably drilled in
irregular or spiral rows, with the first hole not less than one-half
inch from the wall of the pipe. Many engineers object to the use of a
perforated sampling nipple because it ordinarily indicates a higher
percentage of moisture than is actually present in the steam. This is
due to the fact that if the perforations come close to the inner surface
of the pipe, the moisture, which in many instances clings to this
surface, will flow into the calorimeter and cause a large error. Where a
perforated nipple is used, in general it may be said that the
perforations should be at least one inch from the inner pipe surface.
A sampling nipple, open at the inner end and unperforated, undoubtedly
gives as accurate a measure as can be obtained of the moisture in the
steam passing that end. It would appear that a satisfactory method of
obtaining an average sample of the steam would result from the use of an
open end unperforated nipple passing through a stuffing box which would
allow the end to be placed at any point across the diameter of the steam
pipe.