Stokers--The term "automatic stoker" oftentimes conveys the erroneous
impression that such an apparatus takes care of itself, and it must be
thoroughly understood that any stoker requires expert attention to as
high if not higher degree than do hand-fired furnaces.
Stoker-fired furnaces have many advantages over hand firing, but where a
stoker installation is contemplated there are many factors to be
considered. It is true that stokers feed coal to the fire automatically,
but if the coal has first to be fed to the stoker hopper by hand, its
automatic advantage is lost. This is as true of the removal of ash from
a stoker. In a general way, it may be stated that a stoker installation
is not advantageous except possibly for diminishing smoke, unless the
automatic feature is carried to the handling of the coal and ash, as
where coal and ash handling apparatus is not installed there is no
saving in labor. In large plants, however, stokers used in conjunction
with the modern methods of coal storage and coal and ash handling, make
possible a large labor saving. In small plants the labor saving for
stokers over hand-fired furnaces is negligible, and the expense of the
installation no less proportionately than in large plants. Stokers are,
therefore, advisable in small plants only where the saving in fuel will
be large, or where the smoke question is important.
Interest on investment, repairs, depreciation and steam required for
blast and stoker drive must all be considered. The upkeep cost will, in
general, be higher than for hand-fired furnaces. Stokers, however, make
possible the use of cheaper fuels with as high or higher economy than is
obtainable under operating conditions in hand-fired furnaces with a
better grade of fuel. The better efficiency obtainable with a good
stoker is due to more even and continuous firing as against the
intermittent firing of hand-fired furnaces; constant air supply as
against a variation in this supply to meet varying furnace conditions in
hand-fired furnaces; and the doing away to a great extent with the
necessity of working the fires.
Stokers under ordinary operating conditions will give more nearly
smokeless combustion than will hand-fired furnaces and for this reason
must often be installed regardless of other considerations. While a
constant air supply for a given power is theoretically secured by the
use of a stoker, and in many instances the draft is automatically
governed, the air supply should, nevertheless, be as carefully watched
and checked by flue gas analyses as in the case of hand-fired furnaces.
There is a tendency in all stokers to cause the loss of some good fuel
or siftings in the ashpit, but suitable arrangements may be made to
reclaim this.