Steam, Its Generation and UseBabcock & Wilcox Company
History
Steam, Its Generation and Use
Babcock & Wilcox Company
Steam-boilers, Water-tube
In hand-fired furnaces much can be accomplished by proper firing. A
combination of the alternate and spreading methods should be used, the
coal being fired evenly, quickly, lightly and often, and the fires
worked as little as possible. Smoke can be diminished by giving the
gases a long travel under the action of heated brickwork before they
strike the boiler heating surfaces. Air introduced over the fires and
the use of heated arches, etc., for mingling the air with the gases
distilled from the coal will also diminish smoke. Extension furnaces
will undoubtedly lessen smoke where hand firing is used, due to the
increase in length of gas travel and the fact that this travel is
partially under heated brickwork. Where hand-fired grates are
immediately under the boiler tubes, and a high volatile coal is used, if
sufficient combustion space is not provided the volatile gases,
distilled as soon as the coal is thrown on the fire, strike the tube
surfaces and are cooled below the burning point before they are wholly
consumed and pass through as smoke. With an extension furnace, these
volatile gases are acted upon by the radiant heat from the extension
furnace arch and this heat, together with the added length of travel
causes their more complete combustion before striking the heating
surfaces than in the former case.
Smoke may be diminished by employing a baffle arrangement which gives
the gases a fairly long travel under heated brickwork and by introducing
air above the fire. In many cases, however, special furnaces for smoke
reduction are installed at the expense of capacity and economy.
From the standpoint of smokelessness, undoubtedly the best results are
obtained with a good stoker, properly operated. As stated above, the
best stoker will cause smoke under certain conditions. Intelligently
handled, however, under ordinary operating conditions, stoker-fired
furnaces are much more nearly smokeless than those which are hand fired,
and are, to all intents and purposes, smokeless. In practically all
stoker installations there enters the element of time for combustion,
the volatile gases as they are distilled being acted upon by ignition or
other arches before they strike the heating surfaces. In many instances
too, stokers are installed with an extension beyond the boiler front,
which gives an added length of travel during which, the gases are acted
upon by the radiant heat from the ignition or supplementary arches, and
here again we see the long travel giving time for the volatile gases to
be properly consumed.
To repeat, it must be emphatically borne in mind that the question of
smokelessness is largely one of degree, and dependent to an extent much
greater than is ordinarily appreciated upon the handling of the fuel and
the furnaces by the operators, be these furnaces hand fired or
automatically fired.