As already stated, the volume of gases from oil-fired boilers being less
than in the case of coal, makes it evident that the area of stacks for
oil fuel will be less than for coal. It is assumed that these areas will
vary directly as the volume of the gases to be handled, and this volume
for oil may be taken as approximately 60 per cent of that for coal.
In designing stacks for oil fuel there are two features which must not
be overlooked. In coal-firing practice there is rarely danger of too
much draft. In the burning of oil, however, this may play an important
part in the reduction of plant economy, the influence of excessive draft
being more apparent where the load on the plant may be reduced at
intervals. The reason for this is that, aside from a slight decrease in
temperature at reduced loads, the tendency, due to careless firing, is
toward a constant gas flow through the boiler regardless of the rate of
operation, with the corresponding increase of excess air at light loads.
With excessive stack height, economical operation at varying loads is
almost impossible with hand control. With automatic control, however,
where stacks are necessarily high to take care of known peaks, under
lighter loads this economical operation becomes less difficult. For this
reason the question of designing a stack for a plant where the load is
known to be nearly a constant is easier than for a plant where the load
will vary over a wide range. While great care must be taken to avoid
excessive draft, still more care must be taken to assure a draft suction
within all parts of the setting under any and all conditions of
operation. It is very easily possible to more than offset the economy
gained through low draft, by the losses due to setting deterioration,
resulting from such lack of suction. Under conditions where the suction
is not sufficient to carry off the products of combustion, the action of
the heat on the setting brickwork will cause its rapid failure.
[Illustration: 7800 Horse-power Installation of Babcock & Wilcox
Boilers, Equipped with Babcock & Wilcox Chain Grate Stokers at the
Metropolitan West Side Elevated Ry. Co., Chicago, Ill.]
It becomes evident, therefore, that the question of stack height for
oil-fired boilers is one which must be considered with the greatest of
care. The designer, on the one hand, must guard against the evils of
excessive draft with the view to plant economy, and, on the other,
against the evils of lack of draft from the viewpoint of upkeep cost.
Stacks for this work should be proportioned to give ample draft for the
maximum overload that a plant will be called upon to carry, all
conditions of overload carefully considered. At the same time, where
this maximum overload is figured liberally enough to insure a draft
suction within the setting under all conditions, care must be taken
against the installation of a stack which would give more than this
maximum draft.
TABLE 56