Steam, Its Generation and UseBabcock & Wilcox Company
History
Steam, Its Generation and Use
Babcock & Wilcox Company
Steam-boilers, Water-tube
A method of basing the horse power rating of a boiler adopted by boiler
manufacturers is that of heating surfaces. Such a method is absolutely
arbitrary and changes in no way the definition of a boiler horse power
just given. It is simply a statement by the manufacturer that his
product, under ordinary operating conditions or conditions which may be
specified, will evaporate 34.5 pounds of water from and at 212 degrees
per definite amount of heating surface provided. The amount of heating
surface that has been considered by manufacturers capable of evaporating
34.5 pounds from and at 212 degrees per hour has changed from time to
time as the art has progressed. At the present time 10 square feet of
heating surface is ordinarily considered the equivalent of one boiler
horse power among manufacturers of stationary boilers. In view of the
arbitrary nature of such rating and of the widely varying rates of
evaporation possible per square foot of heating surface with different
boilers and different operating conditions, such a basis of rating has
in reality no particular bearing on the question of horse power and
should be considered merely as a convenience.
The whole question of a unit of boiler capacity has been widely
discussed with a view to the adoption of a standard to which there would
appear to be a more rational and definite basis. Many suggestions have
been offered as to such a basis but up to the present time there has
been none which has met with universal approval or which would appear
likely to be generally adopted.
With the meaning of boiler horse power as given above, that is, a
measure of evaporation, it is evident that the capacity of a boiler is a
measure of the power it can develop expressed in boiler horse power.
Since it is necessary, as stated, for boiler manufacturers to adopt a
standard for reasons of convenience in selling, the horse power for
which a boiler is sold is known as its normal rated capacity.
The efficiency of a boiler and the maximum capacity it will develop can
be determined accurately only by a boiler test. The standard methods of
conducting such tests are given on the following pages, these methods
being the recommendations of the Power Test Committee of the American
Society of Mechanical Engineers brought out in 1913.[61] Certain changes
have been made to incorporate in the boiler code such portions of the
"Instructions Regarding Tests in General" as apply to boiler testing.
Methods of calculation and such matter as are treated in other portions
of the book have been omitted from the code as noted.
[Illustration: Portion of 2600 Horse-power Installation of Babcock &
Wilcox Boilers, Equipped with Babcock & Wilcox Chain Grate Stokers at
the Peter Schoenhofen Brewing Co., Chicago, Ill.]
1. OBJECT