Steam, Its Generation and UseBabcock & Wilcox Company
History
Steam, Its Generation and Use
Babcock & Wilcox Company
Steam-boilers, Water-tube
and the various observations made as noted. In the case of a
large boiler having several furnace doors requiring the fire to
be cleaned in sections one after the other, the above directions
pertaining to starting and stopping in a plant of several
boilers may be followed.
To obtain the desired equality of conditions of the fire when a
mechanical stoker other than a chain grate is used, the procedure should
be modified where practicable as follows:
Regulate the coal feed so as to burn the fire to the low
condition required for cleaning. Shut off the coal-feeding
mechanism and fill the hoppers level full. Clean the ash or dump
plate, note quickly the depth and condition of the coal on the
grate, the water level,[66] the steam pressure, and the time,
and record the latter as the starting time. Then start the
coal-feeding mechanism, clean the ashpit, and proceed with the
regular work of the test.
When the time arrives for the close of the test, shut off the
coal-feeding mechanism, fill the hoppers and burn the fire to
the same low point as at the beginning. When this condition is
reached, note the water level, the steam pressure, and the time,
and record the latter as the stopping time. Finally clean the
ashplate and haul the ashes.
In the case of chain grate stokers, the desired operating
conditions should be maintained for half an hour before starting
a test and for a like period before its close, the height of the
throat plate and the speed of the grate being the same during
both of these periods.
8. RECORDS
A log of the data should be entered in notebooks or on blank sheets
suitably prepared in advance. This should be done in such manner that
the test may be divided into hourly periods, or if necessary, periods of
less duration, and the leading data obtained for any one or more periods
as desired, thereby showing the degree of uniformity obtained.
Half-hourly readings of the instruments are usually sufficient. If there
are sudden and wide fluctuations, the readings in such cases should be
taken every 15 minutes, and in some instances oftener.
The coal should be weighed and delivered to the firemen in
portions sufficient for one hour's run, thereby ascertaining the
degree of uniformity of firing. An ample supply of coal should
be maintained at all times, but the quantity on the floor at the
end of each hour should be as small as practicable, so that the
same may be readily estimated and deducted from the total
weight.
The records should be such as to ascertain also the consumption
of feed water each hour and thereby determine the degree of
uniformity of evaporation.
9. QUALITY OF STEAM[67]