The amount of coagulant which can be safely used is dependent upon
the alkalinity of the raw water. When sulphate of alumina is added
to water it is decomposed, as explained above, with the formation
of alumina, which is alone useful in the work of purification, and
sulphuric acid, which combines with the calcium carbonate or lime
present in the water. There should always be an excess of alkalinity or
lime in the raw water. If for any reason there is not, there is nothing
to combine with the liberated sulphuric acid, and the decomposition of
the coagulant is not complete, and a portion of it goes undecomposed
into the effluent. The effluent then has an acid reaction, and is unfit
for domestic supply. When distributed through iron pipes, it attacks
the iron, rusting the pipes, and giving rise to all the disagreeable
consequences of an iron containing water.
The amount of lime in a water available to combine with the sulphuric
acid can be determined by a very simple chemical operation, namely,
by titration with standard acid with a suitable indicator. The amount
of coagulant corresponding to a given quantity of lime can be readily
and accurately calculated, but it is not regarded safe to use as
much sulphate of alumina as corresponds to the lime. The quantity of
coagulant used is not susceptible to exact control, but fluctuates
somewhat, and if the exact theoretical quantity should be employed
during 24 hours, there would surely be an excess during some portion of
that time from which bad results would be experienced. It is therefore
considered only prudent to use three quarters as much sulphate of
alumina as corresponds to the lime in the water. With sulphate of
alumina containing 17 per cent of soluble aluminum oxide and the
corresponding amount of sulphuric acid, the amount which can be applied
to a water in grains per gallon is slightly less than the alkalinity
expressed in terms of parts in 100,000 of calcium carbonate.
Many waters contain sufficient lime to combine with the acid of all
the coagulant which is necessary for their coagulation. Others will
not, and it thus becomes an important matter to determine whether a
given water is capable of decomposing sufficient coagulant for its
treatment. It is usually the flood-flows of rivers which control in
this respect. The water at such times requires much larger quantities
of coagulant for its clarification, and it also usually contains much
less lime than the low-water flows. The reason for this is obviously
that the water of the flood-flows is largely rain-water which has come
over the surface without coming into very intimate contact with the
soil, and consequently without having taken from it much lime, while
the low-water flows contain a considerable proportion of water which
has percolated through the soil and has thus become charged with lime.