The water is pumped through rising mains to reservoirs holding
37,000,000 gallons, not including the Tivoli low-service reservoir,
which is usually supplied from gravity sources. The reservoir capacity
is such that the pumping can be suspended at Quackenbush Street
for considerable periods if necessary, and in practice it has been
suspended at certain times, especially on Sundays. The amount of water
required is also somewhat irregular. The drainage areas supplying the
gravity reservoirs are much larger, relatively, than the reservoirs,
and at flood periods the volume of the gravity supply is much greater
than that which can be drawn in dry weather. Thus it happens that, at
certain seasons of the year, the amount of water to be pumped is but a
fraction of the nominal capacity of the pumps, and at these times it is
possible to shut the pumps down for greater lengths of time.
=Capacity of Pure-water Reservoir.=—The storage capacity provided
between the filters and the Quackenbush Street pumps is comparatively
small, namely, 600,000 gallons, or one hour’s supply at the full
nominal rate. A larger basin, holding as much as one third or one
half of a day’s supply, would be in many respects desirable in this
position, but the conditions were such as to make it practically
impossible. The bottom of the reservoir could not be put lower without
deepening and increasing greatly the expense of the conduit-line. On
the other hand, the flow-line of the reservoir could not be raised
without raising the level of the filters, which was hardly possible
upon the site selected. The available depth of the reservoir was thus
limited between very narrow bounds, and to secure a large capacity
would have necessitated a very large area, and consequently a great
expense. Under these circumstances, and especially in view of the
abundant storage capacity for filtered water in the distributing
reservoirs, it was not deemed necessary to provide a large storage, and
only so much was provided as would allow the pumps to be started at
the convenience of the engineer, and give a reasonable length of time
for the filters to be brought into operation. For this the pure-water
reservoir is ample, but it is not enough to balance any continued
fluctuations in the rate of pumping.