The Municipal and Sanitary Engineer's HandbookBoulnois, H. Percy (Henry Percy)
Science
The Municipal and Sanitary Engineer's Handbook
Boulnois, H. Percy (Henry Percy)
Municipal engineering; Sanitary engineering
In this country, the rule has generally been adopted that public street
lamps burning 5 cube feet per hour of 15 candle gas should not be placed
at a greater distance than 60 yards apart, the average distance in most
English towns being about 40 yards.
On this question, the following interesting particulars by Monsieur
Servier will be of special interest.[115]
It appears to M. Servier that up to the present there has been too much
straining after intensity, with insufficient care for the object of
obtaining a proper quantity of light uniformly spread over the surface
of the ground. The paper in question is therefore intended in the first
place to elucidate this latter subject, so as to determine beforehand
the necessary intensity for luminous centres, gas or electric, and also
their height from the ground and distance from each other required to
produce a certain effect. With this purpose M. Servier proposes to
determine for any point of the road-surface, by the law of the squares
of the distances, the intensity of light, in terms of the Carcel
standard, which is spread at that point by one or more lights of given
power. Representing these intensities by proportional ordinates, the
extremities of these ordinates form an irregular surface, and the volume
contained between this surface and that of the roadway represents a
specific value equivalent to the total luminous intensity distributed
over the soil. In default of a better term, M. Servier calls this a
volume of _cubic Carcels_, a cubic Carcel being the intensity of a
Carcel (9·5 standard candles) multiplied by a square mètre of surface.
The different cases capable of being valued in this manner are as
follows:
1. A burner consuming 140 litres (5 cubic feet nearly), and of 1·1
Carcels (10·45 candles) illuminating power, placed at the height of 3
mètres (9 feet 6 inches). This burner gives at the foot of the
lamp-pillar a maximum intensity of 0·122 Carcel (1·159 candles), and at
10 mètres (32·8 feet) away the illuminating power is reduced to 0·01
Carcel (0·095 candle). The distance of 20 to 30 mètres kept between the
street lamps, even in the best-lighted towns, is therefore excessive,
for these should not be more than 13 mètres (14 yards) apart in order to
obtain between them the minimum illuminating power of 0·05 Carcel (0·475
candle), sufficient for enabling passengers to read.