This result differs somewhat from the one previously obtained,
but there remains a third method, which we can now make trial
of--namely, Saph and Schoder's formula for the discharge of
water mains, V = 174 3rd_root(R^2) x S^.51*. Substituting
values similar to those taken previously, this formula can be
written
2497/(15 pi d^2) = 174 x 3rd_root(d_2)/3rd_root(4^2) x
1^.51/300^.51
or d^2 x 3rd_root(d^2) = 3rd_root(d^6) = (2497 x 3rd_root(16) x
300^.51) / (174 x 15 x 3.14159)
or* log d = 3/8 (3.397419 + 0.401373 + (54 x 2.477121) -
2.240549 - 1.176091 - 0.497150) = 3/8 (1.222647) = 0.458493
* d = 2.874* feet = 34.388 say 34 1/2 inches.
By Neville's general formula the velocity in feet per second =
140 SQRT(RS)-11(RS)^(1/3) or, assuming a diameter of 37 inches,
V = 140 X SQRT(37/(12 x 4) x 1/300) - 11 (37/(12x4x300))^(1/3)
= 140 x SQRT(37/14400) - 11 (37/1440)^(1/3)
= 7.09660 - 1.50656 = 5.59 feet per second.
Discharge = area x velocity; therefore, the discharge in cubic
feet per minute
= 5.59 x 60 x (3.14159 x 37^2)/(4*12^2) = 2504 compared with
2,497 c.f.m, required, showing that if this formula is used the
pipe should be 37 in diameter.
The four formulæ, therefore, give different results, as
follows:--
Hawksley = 40 in
Neville = 37 in
Santo Crimp = 36 in
Saph and Schoder = 34-1/2 in
The circumstances of the case would probably be met by
constructing the outfall 36 in in diameter.
It is very rarely desirable to fix a flap-valve at the end of a
sea outfall pipe, as it forms a serious obstruction to the flow
of the sewage, amounting, in one case the writer investigated,
to a loss of eight-ninths of the available head; the head was
exceptionally small, and the flap valve practically absorbed it
all. The only advantage in using a flap valve occurs when the
pipe is directly connected with a tank sewer below the level of
high water, in which case, if the sea water were allowed to
enter, it would not only occupy space required for storing
sewage, but it would act on the sewage and speedily start
decomposition, with the consequent emission of objectionable
odours. If there is any probability of sand drifting over the
mouth of the outfall pipe, the latter will keep free much
better if there is no valve. Schemes have been suggested in
which it was proposed to utilise a flap valve on the outlet so
as to render the discharge of the sewage automatic. That is to
say, the sewage was proposed to be collected in a reservoir at
the head of, and directly connected to, the outfall pipe, at
the outlet end of which a flap valve was to be fixed. During
high water the mouth of the outfall would be closed, so that
sewage would collect in the pipes, and in the reservoir beyond;
then when the tide had fallen such a distance that its level
was below the level of the sewage, the flap valve would open,
and the sewage flow out until the tide rose and closed the
valve. There are several objections to this arrangement. First