This practically amounts to the common F/15 ratio for an aperture of
approximately 5 inches. For smaller apertures a greater ratio can be
well used, for larger, a relatively longer focus is indicated, the
penalty being light spread into a halo over the diffraction image and
reducing faint contrasts somewhat seriously.
This is one of the factors aside from atmosphere, interfering with
the full advantage of large apertures in refractors. While as already
noted small amounts of spherical aberration may be to a certain
extent focussed out, the sign of _df_ must change with the sign of
the residual aberration, and a quick and certain test of the presence
of spherical aberration is a variation in the appearance of the image
inside and outside focus.
To emphasize the importance of exact knowledge of existing aberrations
note Fig. 187, which shows the results of Hartmann tests on a typical
group of the world’s large objectives. All show traces of residual
zones, but differing greatly in magnitude and position as the attached
scales show. The most conspicuous aberrations are in the big Potsdam
photographic refractor, the least are in the 24 inch Lowell refractor.
The former has since been refigured by Schmidt and revised data are not
yet available; the latter received its final figure from the Lundins
after the last of the Clarks had passed on.
Now a glance at the curves shows that the bad zone of the Potsdam glass
was originally near the periphery, (I), hence both involved large area
and, from Conrady’s equation, seriously enlarged _df_ due to the large
relative aperture at the zone. An aberrant zone near the axis as in the
stage (III) of the Potsdam objective or in the Ottawa 15 inch objective
is much less harmful for corresponding reasons. Such differences have
a direct bearing on the use of stops, since these may do good in case
of peripheral aberration and harm when the faults are axial. Unless
the aberrations are known no general conclusions can be drawn as to
the effect of stops. Even in the Lowell telescope shown as a whole in
Fig. 188, the late Dr. Lowell found stops to be useful in keeping down
atmospheric troubles and reducing the illumination although they could
have had no effect in relation to figure. Fig. 188 shows at the head
of the tube a fitting for a big iris diaphragm, controlled from the
eye-end, the value of which was well demonstrated by numerous observers.
There are, too, cases in which a small instrument, despite intrinsic
lack of resolving power, may actually do better work than a big one.
Such are met in instances where extreme contrast of details is
sought, as has been well pointed out by Nutting (Ap. J. =40=, 33) and
the situation disclosed by him finds amplification in the extraordinary
work done by Barnard with a cheap lantern lens of 1½ inch diameter
and 5½ inches focus (Pop. Ast., =6=, 452).
[Illustration: FIG. 187.—Hartmann Tests of Telescopes [From Hartmann’s
Measures].]
Public-domain text, read in full here on John Shaqi.