Torpedoes and Torpedo Warfare: Containing a Complete and Concise Account of the Rise and Progress of Submarine WarfareSleeman, Charles William
History
Torpedoes and Torpedo Warfare: Containing a Complete and Concise Account of the Rise and Progress of Submarine Warfare
Sleeman, Charles William
Torpedoes
By the employment of electricity and a mirror, the great defect of this
method, viz., the necessity of employing four people to manipulate it,
would be remedied. The foregoing is a modification of Siemens's method
of ascertaining distances at sea, &c.
_Rules observed in Planting Mines._--In placing a system of submarine
mines in position, the following are some of the chief points to
be attended to, this work depending in a great measure on local
circumstances, and on the method that is to be adopted in exploding and
mooring them:--
1.--The plan of defence must be carefully laid down
on a chart, on a scale of not less than six inches
to the mile, and on this plan are to be marked the
sites of the observing stations, the positions of each
mine, circuit closer, and junction box, with their
corresponding numbers, and also of the electric cables.
2.--The position of each mine having been determined,
should be marked off by buoys.
3.--The utmost care should be taken to lay the electric
cables, so that they shall be as far as possible away
from the mines in the vicinity of which it may be
necessary to take them, so as to lessen the liability
of injury to them, by the explosion of the latter.
4.--The electric cables should be laid parallel, and
never be allowed to cross directly over each other,
otherwise the operation of underrunning them will be
much complicated, also a certain amount of slack should
be allowed to facilitate in picking the cables up for
repair, &c.
5.--Every manner of device is to be used to conceal the
electric cables, such as laying dummies, making detours
inland, &c.
6.--All marks indicating position of the mines to be
removed, after the mines have been placed in position.
7.--The identity of each cable and mine to be very
carefully preserved throughout, by means of a number.
8.--A number of electro contact mines should be
placed in advance of the leading line of mines, at
irregular intervals, to prevent the enemy, having once
ascertained the position of one mine of a line, from
knowing within limits the position of the others of
that line.
[Illustration: SYSTEMS OF DEFENCE BY SUBMARINE MINES.
PLATE XVIII]
In connection with a system of defence by electrical submarine mines,
the following batteries are required:--
1.--Firing battery.
2.--Signalling, or shutter battery.
3.--Testing battery.
4.--Telegraph battery.
_Firing Battery._--The firing battery should be suited to the nature of
the fuze employed, and should possess considerable excess of power to
enable it to overcome accidental defects, such as increased resistance
in the various connections, or defective insulation in the line wire,
&c.